Single-
0.1
3G3M1-
phase
AB001-ECT
0.2
200 V
3G3M1-
AB002-ECT
0.4
3G3M1-
AB004-ECT
0.55
0.75
3G3M1-
AB007-ECT
1.1
1.5
3G3M1-
AB015-ECT
2.2
3G3M1-
AB022-ECT
3.0
3.7
3G3M1-
AB037-ECT
*1.
The frame size and model of MCCB, RCD or ELCB (with overcurrent protection function) change according to the ca-
pacity of the power transformer. For details on selection method, refer to related technical data.
*2.
The recommended size of wire to the main circuit terminal is the size when PVC wire having an allowable temperature
of 70°C and a rated voltage of 600 V is used, and the ambient temperature is 40°C.
*3.
Only one wire of recommended size can be connected to the ground terminal.
• Use this product on the following power supply system.
Power supply
L1
L2
L3
PEN
TN-C system
M1 Series EtherCAT Type User's Manual (I670)
Molded
case circuit
breaker
(MCCB) or
Main power
earth leak-
supply in-
age circuit
put [L1/R,
breaker
L2/S, L3/
(RCD/
T]
ELCB) rat-
*1
ed current
HHD
5
5
2.5
HND
HHD
HND
10
HHD
HND
10
HHD
15
HND
15
20
HHD
HND
30
30
HHD
20
HND
30
40
4
HHD
40
60
6
Inverter
Power supply
L1
L1/R
L2
L2/S
L3
L3/T
N
G
PE
Recommended wire size (mm
For main circuit
Inverter
ground
*2*3
[
]
*2
2.5
2.5
2.5
2.5
4
4
4
10
6
10
Inverter
Power supply
L1/R
L1
L2/S
L2
L3/T
L3
G
TN-S system
2 Design
2
)
2.5
2.5
0.75
4
6
10
Inverter
L1/R
L2/S
L3/T
N
G
*1
IT system
2-81