Event name
CPU Error
Meaning
A CPU error such as runaway occurred.
Source
EtherCAT Master Function Mod-
ule
Error attrib-
Level
utes
Effects
User program
Indicators
EtherCAT NET RUN
---
System-de-
Variable
fined varia-
None
bles
Cause and
Assumed cause
correction
(1) Strong ambient noise was re-
ceived.
Attached in-
None
formation
Precautions/
None
Remarks
M1 Series EtherCAT Type User's Manual (I670)
Source details Slave
Minor fault
Recovery
Continues.
Operation
EtherCAT NET ERR
---
Data type
None
Correction
Check the measures against
noise (grounding condition, sig-
nal line or communications cable/
main circuit wiring and installa-
tion method, etc.).
→ Improve the measures against
noise.
Event code
183E0000 hex
Detection tim-
ing
Error reset
Log category
Motor stops.
EtherCAT LINK/ACT
---
Name
None
Prevention
Excessive noise may be generat-
ed around the inverter. Consider
taking measures against noise.