Event name
Life Warning
Meaning
The main circuit capacitor, PCB electrolytic capacitor, or cooling fan reached the end of life.
Source
EtherCAT Master Function Mod-
ule
Error attrib-
Level
utes
Effects
User program
Indicators
EtherCAT NET RUN
---
System-de-
Variable
fined varia-
None
bles
Cause and
Assumed cause
correction
(1) Life warning
Attached in-
None
formation
Precautions/
None
Remarks
M1 Series EtherCAT Type User's Manual (I670)
Source details Slave
Observation
Recovery
Continues.
Operation
EtherCAT NET ERR
---
Data type
None
Correction
Check the main circuit capacitor,
PCB electrolytic capacitor, and
cumulative run time of cooling
fan.
→ Replace the inverter.