Omron M1 Series User Manual page 47

Multi-function compact inverter
Hide thumbs Also See for M1 Series:
Table of Contents

Advertisement

Item
Rated input voltage
Rated input cur-
*4
rent [A]
Rated output voltage
Rated output cur-
*5
rent [A]
*6
Braking torque
[%]
Braking
Regenerative
resistor
braking
circuit
Minimum con-
nection resist-
ance [Ω]
Short circuit current rating
[kA]
Weight [kg]
*1.
The maximum applicable motor capacity is given for a standard four-phase motor. When selecting an inver-
ter, select not just by kW but also ensure that the inverter rated output current is greater than the motor rat-
ed current.
*2.
In calculating the rated capacity, the rated output voltage is assumed to be 200 V or 240 V.
*3.
A voltage higher than the power supply voltage cannot be output.
*4.
When Carrier Frequency (3004Hex-1BHex) is set to the following or below, derating is required.
HHD mode...AB001 to A2037: 8 kHz
HND mode...AB001 to A2022: 4 kHz
For derating, refer to A-1 Derating Table on page A-2.
*5.
The following shows the calculated value when the power supply capacity is 500 kVA (10x the inverter ca-
pacity when the inverter capacity exceeds 50 kVA) and when a %X = 5% power supply is connected.
*6.
The numeric value is the average braking torque per individual motor. (Varies according to motor efficiency)
*7.
Allowable ambient temperature of 40°C or below of AB004, AB007, AB015 and AB022.
The rated output current in the HND mode decreases by 2% for every temperature increase of 1°C when
the ambient temperature is 40°C or more.
*8.
The maximum applicable motor capacity is 2.2 kW when the input voltage is 220 to 240 V.
*9.
The maximum applicable motor capacity is 3.0 kW when the input voltage is 220 to 240 V.
Common Specifications
Item
*1
Enclosure rating
M1 Series EtherCAT Type User's Manual (I670)
*3
HHD
1.8
3.3
HND
3.3
4.9
HHD
1
1.6
HND
1.2
1.9
HHD
150
HND
75
Built-in braking resistor circuit (discharge resistor separately mounted)
100 to 120
Approx.
Approx.
0.5
0.5
Open type (IP20)
Single-phase 200 V
Single-phase 200 to 240 V, 50/60 Hz
5.4
9.7
7.3
13.8
Single-phase 200 to 240 V (with AVR)
3
5
*7
*7
3.5
6.0
100
73
68
100
Approx.
Approx.
Approx.
0.7
0.9
Specifications
1 Overview
16.4
22
45.4
20.2
26
-
8
11
17.5
*7
*7
-
9.6
12
70
40
40
48
29
-
40 to 120
Approx.
Approx.
1.5
1.7
3.8
1-13
1

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading