8 Other Functions
Bias = 0%, Bias base point = 0%
PID process command
100%
-100%
• PID command by communication (300EHex-03Hex = 4)
Communication parameter (3002Hex-0EHex): Transmission data 20000d/100% PID command
PID Control Feedback Selection (301FHex-14Hex)
• 301FHex-14Hex = 0: Analog input
If "0: Analog input" is selected for PID Control Feedback Selection (301FHex-14Hex), allocate "5:
PID feedback value" to Input Terminal [AI1] Function Selection (3005Hex-3EHex). The analog input
value is internally controlled as 0% to 100%. For details on analog input, refer to 8-3-1 Analog Input
(Function Selection) on page 8-32.
When analog input is applied to PID feedback, the following gains, biases, filters and offsets are appli-
cable.
Input ter-
Input range
minal
0 to +10V,
AI1
-10 to +10V
• 301FHex-14Hex = 3: Pulse train input
If "3: Pulse train input" is set to PID Control Feedback Selection (301FHex-14Hex), the inverter cap-
tures a value converted into a percentage with the maximum frequency as 100% where the pulse
correction factor (3024Hex-07Hex/3024Hex-08Hex) is multiplied with the frequency value [kP/s] of
the captured pulse train input.
8-116
Gain
B point
0%
100%
Gain
base point
-100%
Bias
Base
Bias
point
3006Hex-
3006Hex-
38Hex
39Hex
Bias ≠ 0%, Bias base point ≠ 0%
PID process command
100%
Gain
Analog
input
-100%
Bias
Gain
Base
Gain
point
3006Hex-
3006Hex-
21Hex
23Hex
M1 Series EtherCAT Type User's Manual (I670)
B point
Bias base
point
Analog
input
0%
100%
Gain
base point
A point
Polarity
selection
(Range
Filter
Offset
selec-
tion)
3006Hex-
3006Hex-
3006Hex-
24Hex
22Hex
20Hex