Maintenance And Inspection - Omron SYSDRIVE 3G3EV-AB004-CE User Manual

Compact low-noise inverter
Table of Contents

Advertisement

Operation
Under the wiring condition shown below, if the control output power supply is lower than
24 VDC or if it is set to OFF, current may flow in the direction shown by the arrows and
may operate the Inverter input. In such a case, insert a diode in the A section shown
below.

5-3 Maintenance and Inspection

H Daily Inspection
While the system is operating, check the following items:
•Check the motor for noise.
•Check for abnormal heating.
•Check if the ambient temperature is too high.
•Check if the output current monitor display indicates a higher value than usual.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
A section
24 V
SF
SR
S1 to
S3
3.3 K
360
SC
0.1µ
GND
Chapter 5
5-13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysdrive 3g3ev

Table of Contents