Troubleshooting The Mx240 Mics - Juniper MX240 Hardware Manual

Universal routing platform.
Hide thumbs Also See for MX240:
Table of Contents

Advertisement

Start time:
Uptime:
Slot 10 information:
State
Temperature
Total CPU DRAM
Total RLDRAM
Total DDR DRAM
Start time:
Uptime:
For further description of the output from the commands, see the Junos OS Administration Library.
SEE ALSO
MX240 Flexible PIC Concentrator (FPC) LEDs | 124
Maintaining MX240 FPCs | 324
Holding an MX240 FPC | 326
Storing an MX240 FPC | 330

Troubleshooting the MX240 MICs

Problem
Description: The MICs are not functioning normally.
Solution
Check the status of each port on a MIC by looking at the LED located on the MIC faceplate. For
information about the meaning of LED states on different MICs, see the
Reference.
Check the status of a MIC by issuing the show chassis fpc pic-status CLI command. The MIC slots in
the MPC are labeled PIC 0/1 and PIC 2/3, left to right:
user@host> show chassis fpc pic-status
Slot 0
Online
PIC 0
Online
PIC 1
Online
Slot 1
Online
2008-12-11 16:53:18 PST
15 hours, 2 minutes, 53 seconds
Online
24 degrees C / 75 degrees F