Normally-open type:
1.
Check for continuity between the terminals.
• There should
be
continuity between
the
NO.1 and
No.2 terminals
when
power
and
ground are
con-
nected
to the
NO.3
and
No.4 terminals.
•
There should be no
continuity
between the No.1
and No.2 terminals when power is disconnected.
\
Terminal
1
2
Power
(No.3
-
No.4)
\
Disconnected
Connected
1
3
B
2
4
•
Power window
relay
•
Radiator fan relay
•
Condenser
fan relay
•
AJe
compressor clutch
relay
•
Reverse relay
(AfT)
•
Horn relay
•
Rear accessory
socket
relay
(AfT)
•
Starter
cut
relay
1
'~'
4
Normally-open
type:
1.
Check for continuity between the terminals
.
•
There should be
continuity
between the No.4 and
No.
3 terminals
when power
and ground are
con-
nected to the No.1 and No.2
terminals .
• There should be no continuity
between
the No.4
and
No.3 terminals when power is disconnected.
\
Terminal
\
4
3
Power
(No.1
- No.2)
Disconnected
Connected
0
D
~..
~
3
2
•
ABS pump motor relay
23-53