2. Installation
• The machine will issue an SC165 error if the machine is powered on with the ICIB-3 removed
and the "Data Security for Copying" feature set to "ON".
• The machine will issue an uncertain SC165 error if the machine is powered on with the defective
ICIB-3 and the "Data Security for Copying" feature set to "OFF".
2
• When you remove this option from the machine, first set the setting to "OFF" with the user tool
before removing this board. If you forget to do this, "Data Security for Copying" feature cannot
appear in the user tool setting. And then SC165 will appear every time the machine is switched
on, and the machine cannot be used.
Make sure that the machine can recognize the option (see "Check All Connections" at the end of this
section).
96
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA