9-424 Cleaning Auger Near Full RAP
Control Logic has detected that the Cleaning Auger is almost full.
Initial Actions
This is a message fault only. An operator action is required
Procedure
This fault should not require any service action. If this fault causes a problem, use the
Cleaning Auger Full RAP
to troubleshoot the problem.
Status Indicator RAPs
9-424 Cleaning Auger Near Full RAP, 9-601 Humidity
9-601 Humidity Out Of Range RAP
The measured humidity was out of the prescribed range.
Initial Actions
•
Refer to BSD 9.14 and BSD 9.15 for the following procedure.
•
Check the Temp Humidity Sensor
Check that the
P/J142
on the Temp Humidity Sensor, and
are firmly connected.
9-358
Procedure
+5 VDC is measured between P/J422B-2 and P/J422A-3 on the IOT Drive PWB.
Y
N
Replace the IOT Drive PWB
Go to
Flag 1
and
Flag 2
on BSD 9.14. Check the wires for an open circuit or a short circuit. If
the wires are good, replace the Temp Humidity Sensor
replace the IOT Drive PWB
(PL
1/05
2-130
manuals4you.com
manuals4you.com
(PL
7.1) for dirt or foreign matter
P/J422A
on the IOT Drive PWB
(PL
9.2).
(PL
7.1). If the problem continues,
9.2).
DocuColor 12/DCCS50
Reissue