Y
N
+24 VDC is measured between P/J23-3 and GND on the IOT LVPS.
Y
N
Go to the
+24 VDC Power (IOT LVPS)
Go to
Flag 1
on BSD 1.2 and check for an open wiring. If the wiring is OK, replace the
Tray PWB
(PL
9.3).
Replace the Tray PWB
(PL
9.3).
Reissue
DocuColor 12/DCCS50
RAP.
7-500 Tray out of position during Job RAP
The machine detected that the Tray is out of position during the Job.
Initial Actions
•
Refer to BSD 7.1 through BSD 7.3 for the following procedure.
•
Ensure the Tray attributes selected match the paper loaded in the Tray.
•
Ensure that the End Guides are properly adjusted to the paper in the Tray.
•
Ensure Connector PJ802 on the Tray PWB is seated properly for Trays 2,3,4.
•
Ensure that there are no obvious crimped or broken wires.
Procedure
Tray 2 was in use when the fault occurred.
Y
N
Tray 3 was in use when the fault occurred.
Y
N
Enter dC330 and Active Stack 008-250 Tray 4 size switch 1, 008-251 Tray 4 size
switch 2, 008-252 Tray 4 size switch 3, 008-253 Tray 4 size switch 4 for the Tray 4
Size Sensor and press Start. Open Tray 4. Check the state of the four Tray Sensors.
The four Tray Sensor States displayed corresponds with Table 3.
Y
N
Check for +XVDC (Refer to Table 3 for the DC Voltages) +XVDC is measured
at TP-8 on the Tray PWB.
Y
N
Check for +XVDC (Refer to Table 3 for the DC Voltages) +XVDC is mea-
sured at P/J415B-14 on the IOT PWB.
Y
N
Go to the
Go to
Flag 1
and
tors. If the harness and connectors are OK, replace the Tray 4 Size Sen-
sor
(PL
2.1).
Replace the Tray PWB
Check/Replace the following parts in the order listed until the problem is resolved.
Replace any parts that are worn, broken, binding, or slipping.
•
Tray 4 Assembly
(PL
•
Tray 4 Size Sensor
Enter dC330 and Active Stack 008-245 Tray 3 size switch 1, 008-246 Tray 3 size switch
2, 008-247 Tray 3 size switch 3, 008-248 Tray 3 size switch 4 for the Tray 3 Size Sensor
and press Start. Open Tray 3. Check the state of the four Tray Sensors. The four Tray
Sensor States displayed corresponds with Table 2.
Y
N
Check for +XVDC (Refer to Table 2 for the DC Voltages) +XVDC is measured at
TP-7 on the Tray PWB.
A
B
1/05
2-73
+5 VDC Power (IOT LVPS)
RAP.
Flag 2
on BSD 7.3 and check the harness and connec-
(PL
9.3).
2.4).
(PL
2.1).
Status Indicator RAPs