15-367 X - Fail 4 RAP
The control logic on the Pre IPS PWB detected a hardware failure.
Initial Actions
•
Refer to BSD 6.7 in the following procedure:
•
Ensure that
P/J560
on the Pre IPS PWB and the BR PWB is fully seated.
Procedure
PO/PO the machine. If the fault continues, replace the following:
•
BR PWB
(PL
3.5)
•
Pre IPS PWB
(PL
3.5)
Reissue
DocuColor 12/DCCS50
15-370 X - Fail 5 RAP
The control logic on the Pre IPS PWB detected a hardware failure.
Initial Actions
Refer to BSD 6.7 in the following procedure:
Procedure
PO/PO the machine. If the fault continues, replace the following:
•
Pre IPS PWB
(PL
3.5)
1/05
15-367 X - Fail 4 RAP, 15-370 X - Fail 5 RAP
2-223
Status Indicator RAPs