Dc131 Procon2 Nvm List (774) - Xerox DocuColor 12/DCCS50 Service Manual

Table of Contents

Advertisement

Table 1 Procon 1 NVM List (773)
Chain-
Link
Name
Default
773-592 ADC Vpatch S [M]
0
773-593 ADC Vpatch S [C]
0
773-594 ADC Vpatch S [K]
0
773-596 ADC Vpatch D [Y]
0
773-597 ADC Vpatch D [M]
0
773-598 ADC Vpatch D [C]
0
773-599 ADC Vpatch D [K]
0
773-606 Radc patch [Y]
0
773-607 Radc patch [M]
0
773-608 Radc patch [C]
0
773-609 Radc patch [K]
0
General Procedures
dC131 Procon1 NVM List (773), dC131 Procon2 NVM
Range
Description
0-65535 M-color: ADC patch measurement
value (Mirror element)
0-65535 C-color: ADC patch measurement
value (Mirror element)
0-65535 K-color: ADC patch measurement
value (Mirror element)
0-65535 Y-color: DSP: ADC patch measure-
ment value (Diffusion element)
0-65535 M-color: DSP: ADC patch measure-
ment value (Diffusion element)
0-65535 C-color: DSP: ADC patch measure-
ment value (Diffusion element)
0-65535 K-color: DSP: ADC patch measure-
ment value (Diffusion element)
0-65535 Y-color: ADC patch measurement
density
0-65535 M-color: ADC patch measurement
density
0-65535 C-color: ADC patch measurement
density
0-65535 K-color: ADC patch measurement
density

dC131 Procon2 NVM List (774)

Chain-
Link
Name
774-001 CC I TOT
774-004 CC V GRID
774-005 CC V GRID DFLT
774-008 BOTTLE NOT IN POSI-
TION
774-015 BOTTLE EMP
COUNTER
774-017 BOTTLE EMP HOLD
774-018 BOTTLE FULL
774-019 BOTTLE FULL
COUNTER
774-020 BOTTLE GOAL
774-029 PCC dC 12
774-033 PCC dC ER
774-056 X CRU TYPE
774-057 CRU COUNT MODE
774-070 DRUM CYCLEUPPER
L
774-071 DRUM CYCLEUPPER
H
1/05
6-86
manuals4you.com
manuals4you.com
Table 1 Procon2 NVM List (774)
Default
Range
717
0-1023
Current total CC electric current
(0=0 micro ampere 1023=1000
micro ampere)
717
0-1023
Current grid CC voltage (0=0V
1023=1000V)
717
0-1023
Grid voltage to check the CC
output (0=0V 1023=1000V)
0
Waste bottle (0=Yes 1=No)
0
EMPTY counter
0
EMP Counter record when the
Bottle Goal was determined.
0
Collection status FLG (0= Empty
1= Near Full 2= Full)
0
Near Full Counter
300
0-65536
Threshold to generate a Bottle
Full Fault
130
0-255
DC current to reduce cycle 1-2
(0=0 micro ampere 255=800
micro ampere)
(If out of the range, MAX value is
output.)
96
0-255
DC current for elimination= Nom-
inal (0=0 micro ampere 255=800
micro ampere)
(If out of the range, MAX value is
output.)
48=FSMA
0-255
Drum unit type (0XAA)
49=T&M
0
0-1
Shut-down condition setting flag
0= Shut-down with the set
count value.
1= Shut-down when
exceeding the set count
value.
0
Drum cycle count: L side count
(0-99)
3400
Drum cycle count: H side count
(0-65535)
DocuColor 12/DCCS50
Description
Reissue

Advertisement

Table of Contents
loading