Xerox DocuColor 12/DCCS50 Service Manual page 755

Table of Contents

Advertisement

Table 1 PH NVM List (761)
Chain-
Link
Name
Default
761-312 PASS Machine
0
EXIT SENSOR 2
DSP: Pass Machine
Exit SNR 2
761-313 PASS Machine
0
EXIT SENSOR 3
761-314 PASS Machine
0
EXIT SENSOR 4
761-315 PASS Machine
0
EXIT SENSOR 5
Reissue
DocuColor 12/DCCS50
Range
Description
None
Measurement result (Last 10): Machine
Exit Sensor OFF timing from Fuser Exit
Sensor OFF.
Default=0ms
Range=None
Theoretical value=221ms (Straight
ejection), 509.7ms+(Paper
lengthmm+7.1mm) / 0.350mm/ms
(Reverse ejection)
Unit=10ms/step
Last storage location - see 761-372.
None
Measurement result (Last 10): Machine
Exit Sensor OFF timing from Fuser Exit
Sensor OFF.
Theoretical value=221ms (Straight
ejection), 509.7ms+(Paper
lengthmm+7.1mm) / 0.350mm/ms
(Reverse ejection)
Unit=10ms/step
Last storage location - see 761-372.
None
Measurement result (Last 10): Machine
Exit Sensor OFF timing from Fuser Exit
Sensor OFF.
Theoretical value=221ms (Straight
ejection), 509.7ms+(Paper
lengthmm+7.1mm) / 0.350mm/ms
(Reverse ejection)
Unit=10ms/step
Last storage location - see 761-372.
None
Measurement result (Last 10): Machine
Exit Sensor OFF timing from Fuser Exit
Sensor OFF.
Theoretical value=221ms (Straight
ejection), 509.7ms+(Paper
lengthmm+7.1mm) / 0.350mm/ms
(Reverse ejection)
Unit=10ms/step
Last storage location - see 761-372.
Table 1 PH NVM List (761)
Chain-
Link
Name
Default
761-316 PASS Machine
0
EXIT SENSOR 6
761-317 PASS Machine
0
EXIT SENSOR 7
761-318 PASS Machine
0
EXIT SENSOR 8
761-319 PASS Machine
0
EXIT SENSOR 9
761-320 PASS Machine
0
EXIT SENSOR 10
1/05
6-75
Range
Description
None
Measurement result (Last 10): Machine
Exit Sensor OFF timing from Fuser Exit
Sensor OFF.
Theoretical value=221ms (Straight
ejection), 509.7ms+(Paper
lengthmm+7.1mm) / 0.350mm/ms
(Reverse ejection)
Unit=10ms/step
Last storage location - see 761-372.
None
Measurement result (Last 10): Machine
Exit Sensor OFF timing from Fuser Exit
Sensor OFF.
Theoretical value=221ms (Straight
ejection), 509.7ms+(Paper
lengthmm+7.1mm) / 0.350mm/ms
(Reverse ejection)
Unit=10ms/step
Last storage location - see 761-372.
None
Measurement result (Last 10): Machine
Exit Sensor OFF timing from Fuser Exit
Sensor OFF.
Theoretical value=221ms (Straight
ejection), 509.7ms+(Paper
lengthmm+7.1mm) / 0.350mm/ms
(Reverse ejection)
Unit=10ms/step
Last storage location - see 761-372.
None
Measurement result (Last 10): Machine
Exit Sensor OFF timing from Fuser Exit
Sensor OFF.
Theoretical value=221ms (Straight
ejection), 509.7ms+(Paper
lengthmm+7.1mm) / 0.350mm/ms
(Reverse ejection)
Unit=10ms/step
Last storage location - see 761-372.
None
Measurement result (Last 10): Machine
Exit Sensor OFF timing from Fuser Exit
Sensor OFF.
Theoretical value=221ms (Straight
ejection), 509.7ms+(Paper
lengthmm+7.1mm) / 0.350mm/ms
(Reverse ejection)
Unit=10ms/step
Last storage location - see 761-372.
General Procedures
dC131PH NVM List (761)

Advertisement

Table of Contents
loading

Table of Contents