NOTE: Lock the shaft support by matching the hole with the frame's half-punch
3).
Figure 3 Lock the shaft support
Repairs and Adjustments
REP 12.10.1
(Figure
NOTE: Make sure that both sides of the Platen Belt are correctly set in the pulley
4).
CORRECT
2.
Connect the power cord and switch on the power.
3.
Select and execute the DC330 Component Control Diag. Screen (005-055 Belt Motor
CW). Press the START button.
4.
Rotate the Platen Belt for 15 seconds. Press the STOP button. Check that the Platen Belt
has not shifted to either side.
1/05
4-174
manuals4you.com
manuals4you.com
INCORRECT
Figure 4 Install the Platen Belt