Xerox DocuColor 12/DCCS50 Service Manual page 754

Table of Contents

Advertisement

Table 1 PH NVM List (761)
Chain-
Link
Name
Default
761-303 ARRIVE AT FUSER
0
EXIT SENSOR 3
DSP: ARRV Fuser
Exit SNR 3
761-304 ARRIVE AT FUSER
0
EXIT SENSOR 4
DSP: ARRV Fuser
Exit SNR 4
761-305 ARRIVE AT FUSER
0
EXIT SENSOR 5
DSP: ARRV Fuser
Exit SNR 5
761-306 ARRIVE AT FUSER
0
EXIT SENSOR 6
DSP: ARRV Fuser
Exit SNR 6
General Procedures
dC131PH NVM List (761)
Range
Description
None
Measurement result: Fuser Exit Sensor
ON timing from Registration Feed start.
Default=0ms
Range=None
Theoretical value=1815ms, 3071ms
(This paper 1), 6655ms (Thick paper
2)
Unit=10ms/step
Last storage location - see 761-371.
None
Measurement result: Fuser Exit Sensor
ON timing from Registration Feed start.
Default=0ms
Range=None
Theoretical value=1815ms, 3071ms
(This paper 1), 6655ms (Thick paper
2)
Unit=10ms/step
Last storage location - see 761-371.
None
Measurement result: Fuser Exit Sensor
ON timing from Registration Feed start.
Default=0ms
Range=None
Theoretical value=1815ms, 3071ms
(This paper 1), 6655ms (Thick paper
2)
Unit=10ms/step
Last storage location - see 761-371.
None
Measurement result: Fuser Exit Sensor
ON timing from Registration Feed start.
Theoretical value=1815ms, 3071ms
(This paper 1), 6655ms (Thick paper
2)
Unit=10ms/step
Last storage location - see 761-371.
Chain-
Link
Name
761-307 ARRIVE AT FUSER
EXIT SENSOR 7
761-308 ARRIVE AT FUSER
EXIT SENSOR 8
761-309 ARRIVE AT FUSER
EXIT SENSOR 9
761-310 ARRIVE AT FUSER
EXIT SENSOR 10
761-311 PASS Machine
EXIT SENSOR 1
1/05
6-74
manuals4you.com
manuals4you.com
Table 1 PH NVM List (761)
Default
Range
Description
0
None
Measurement result: Fuser Exit Sensor
ON timing from Registration Feed start.
Theoretical value=1815ms, 3071ms
(This paper 1), 6655ms (Thick paper
2)
Unit=10ms/step
Last storage location - see 761-371.
0
None
Measurement result: Fuser Exit Sensor
ON timing from Registration Feed start.
Theoretical value=1815ms, 3071ms
(This paper 1), 6655ms (Thick paper
2)
Unit=10ms/step
Last storage location - see 761-371.
0
None
Measurement result: Fuser Exit Sensor
ON timing from Registration Feed start.
Theoretical value=1815ms, 3071ms
(This paper 1), 6655ms (Thick paper
2)
Unit=10ms/step
Last storage location - see 761-371.
0
None
Measurement result: Fuser Exit Sensor
ON timing from Registration Feed start.
Theoretical value=1815ms, 3071ms
(This paper 1), 6655ms (Thick paper
2)
Unit=10ms/step
Last storage location - see 761-371.
0
None
Measurement result (Last 10): Machine
Exit Sensor OFF timing from Fuser Exit
Sensor OFF.
Theoretical value=221ms (Straight
ejection), 509.7ms+(Paper
lengthmm+7.1mm) / 0.350mm/ms
(Reverse ejection)
Unit=10ms/step
Last storage location - see 761-372.
DocuColor 12/DCCS50
Reissue

Advertisement

Table of Contents
loading