3-380 TR0 Fail RAP

A 3-380 fault indicates that the TR0 signal was not received on time.
Initial Actions
Refer to BSD 9.8 for the following procedure.
Ensure that the TR0 Patch (reflector) on the IBT Belt is clean and in good condition.
Ensure that the Belt is installed correctly, with the reflector toward the Inboard edge.
Ensure that
P/J398
on the Half Tone PWB,
IOT Drive PWB,
P/J140
on the TR0 Sensor, and Double Plug P702A/
nected before beginning this RAP.
Ensure that the Drum CRU is properly installed.
Procedure
If Tag 38 is installed on the machine, it is possible that there is a shorting condition between the
EPC Scan Cable and the FPC-ROS Flat Cable connector ( P/J398). Foam on top of the con-
nector is intended to insulate the pins from contact. However, the foam can be compressed by
the EPC Scan Cable and the pins may stick through and short against the Scan Cable connec-
tor housing.
Using a sheet of transparency or shim stock, cut a strip 45mm X 12mm and adhere to the top
of the foam on the FPC-ROS Cable connector ( P/J398). This strip will function as an insula-
tor.
If this does not resolve the problem, or if Tag P-38 is not installed, continue with this procedure.
NOTE: The PWS display may not update the logic level display fast enough to show the state
of the TR0 Sensor. Observe the event Counter. If the event counter advances, the display is
changing.
Go to dC330. Stack the following codes. 004-007 Main Motor, 004-021 Drum Motor, 003-213
TRO Sensor. The display is H and changes to L momentarily.
Y
N
The display is always H.
Y
N
Less than +1 VDC is measured between P/J416A-7 and DC Com.
Y
N
Replace the IOT Drive PWB
Go to
Flag 5
on BSD 9.8. Check the wire for a short circuit to ground. If the wire is
good, replace the TR0 Sensor
(PL
+5 VDC is measured between P/J416A-8 and DC COM
Y
N
Replace the IOT Drive PWB (PL 9.2).
Go to
Flag 5
and
Flag 6
on BSD 9.8. Check the wires for an open circuit. If the wires are
good, replace the TR0 Sensor (PL 7.5).
There is +5 VDC from J395 pin 1 to J395 pin 11 on the Half Tone PWB (BSD 6.5).
Y
N
There is +5 VDC from J19 pin 4 on the AC Driver PWB to GND (BSD 1.4).
A
Reissue
DocuColor 12/DCCS50
P/J345
on the LDD PWB,
P/J416
J702A
(PL
9.2).
7.5).
A
Y
N
Go to
Flag 5
on BSD 1.2 and check the +5 VDC circuit to the AC Driver PWB.
Go to
Flag 1
and
Flag 7
NOTE: The following step requires the use of the Fluke 87 DVM, or other test meter with a volt-
age type diode test function.
Perform the following:
1.
Set the meter rotary switch to the diode test position.
on the
are con-
2.
Disconnect P/J 395 and P/J398 on the Half Tone PWB.
3.
Connect the red (+) lead to J395 pin 1 and the black (COM) lead to J398 pin 1
The meter reads 0.3 VDC or less
Y
N
If the meter reads OL in both directions, CR13 on the Halftone PWB is open; replace the
PWB
(PL
9.2).
Reverse the leads. The meter reads OL.
Y
N
CR13 on the Halftone PWB is shorted; replace the PWB
There is +24 VDC from pin 3 to pin 4 of
Y
N
Go to
Flag 6
of BSD 4.1. Check for an open circuit. Refer to the 24 VDC wirenets as
required.
Check the connections to the Drum Motor. If the connections are secure, replace the Drum
Motor
(PL
1.1). If the problem persists, replace the IOT Drive PWB
1/05
2-21
on BSD 1.4. Check the circuit for Interlocked +5 VDC.
(PL
9.2).
P/J2030
on the Drum Motor.
(PL
Status Indicator RAPs
3-380 TR0 Fail RAP
9.2).