Dc135 Hfsi Counter List - Xerox DocuColor 12/DCCS50 Service Manual

Table of Contents

Advertisement

dC135 HFSI Counters
Purpose
This routine displays the service life (Threshold) and the current value (count) of the periodic
replacement parts. Replacement life change, and current value resets are possible.
Procedure
1.
Enter the Service Diagnostics Mode. Refer to
using the
PWS.
2.
Select Maintenance on the Service Entry Screen. The All Jams screen displays as the
default screen.
3.
Select HFSI Counters (dC135) tab on the Maintenance screen.
4.
The HFSI Counters screen displays the replacement life (Threshold) and the current
value (count) of the periodic replacement parts. Two vertical tabs allow display of all HFSI
counters, or only those counters that are over threshold.
5.
Refer to
Detailed Maintenance Activities
all HSFI counters that are at or near threshold.
6.
To reset the count after replacing the parts, select the appropriate HFSI item, then select
the Reset Counter button.
General Procedures
dC135 HFSI Counters, dC135 HFSI Counter List
Entering the Service Diagnostic Mode
in Section 1. Perform the listed Service Action for

dC135 HFSI Counter List

NOTE: Refer to
Detailed Maintenance Activities
1/05
6-94
manuals4you.com
manuals4you.com
in Section 1.
Reissue