Table 2 Output Component Control Codes
ID
Description
In_Out
012-030 END WALL MOTOR
Output
OPEN
012-031 END WALL MOTOR
Output
CLOSE
012-036 COMPILER TRAY
Output
SOLENOID
012-040 STACKER MOTOR UP Output
012-041 STACKER MOTOR
Output
DOWN
012-053 EJECT PADDLE
Output
MOTOR
012-060 TAMPER MOTOR LOW
Output
FRONT
012-061 TAMPER MOTOR TOP
Output
FRONT
012-062 TAMPER MOTOR LOW
Output
REAR
012-063 TAMPER MOTOR TOP
Output
REAR
012-064 TAMPER MOTOR MID-
Output
DLE FRONT
Reissue
DocuColor 12/DCCS50
Module_I
Smart Help
D
High: On
Finisher
Drives End Wall to open it (300ms)
High: On
Finisher
Drives End Wall to close it (300ms)
Low: On
Finisher
Lowers Compiler Tray.
High: On
Finisher
No output is allowed if a response
is sensed from Tray Upper Limit
SNR before or while Stacker Tray
being driven upward. (500ms)
High: On
Finisher
No output is allowed if a response
is sensed from Tray Upper Limit
SNR before or while Stacker Tray
being driven downward.
High: On
Finisher
Drives Set Clamp. (300ms)
Not measurable
Finisher
Drives Tamper to front at a low
speed. (560pps) (100 pulses)
Note: Not measurable in field due to
24V Clock.
Not measurable
Finisher
Drives Tamper to front at a high
speed. (2000pps) (100 pulses)
Note: Not measurable in field due to
24V Clock.
Not measurable
Finisher
Drives Tamper to rear at a low
speed. (560pps) (100 pulses)
Note: Not measurable in field due to
24V Clock.
Not measurable
Finisher
Drives Tamper to rear at a high
speed. (2000pps) (100 pulses)
Note: Not measurable in field due to
24V Clock.
Not measurable
Finisher
Drives Tamper to front at a medium
speed. (1000pps) (100 pulses)
Note: Not measurable in field due to
24V Clock.
Table 2 Output Component Control Codes
ID
Description
012-065 TAMPER MOTOR MID-
DLE REAR
012-070 FIN GATE SOLENOID-
MBX/SCT POSITION
012-071 FIN GATE SOLENOID-
FINSHER POSITION
012-075 STAPLER MOTOR
CLOSE
012-076 STAPLE POSITION
MOTOR TOP FRONT
012-077 STAPLE POSITION
MOTOR LOW FRONT
012-078 STAPLE POSITION
TOP REAR
012-079 STAPLE POSITION
MOTOR LOW REAR
012-081 MBX GATE SOLE-
NOID CLOSE
1/05
6-113
In_Out
Smart Help
Output
Not measurable
Drives Tamper to rear at a medium
speed. (1000pps) (100 pulses)
Note: Not measurable in field due to
24V Clock.
Output
Low: On
Switches Gate for MBX/SCT. (100
pulses)
Output
Low: On
Switches Gate for Finisher. (100
pulses)
Output
High: On
Does stapling. (Compiler cover
Safety ON) (Stops at Home or
times out in 500ms).
Output
Not measurable
Drives Stapler Unit to front at a high
speed (2700pps). If End Wall Open
Sensor doesn't sense any, no out-
put is allowed. (250 pulses).
Output
Not measurable
Drives Stapler Unit to front at a low
speed (2000pps). If End Wall Open
Sensor doesn't sense any, no out-
put is allowed. (250 pulses).
Note: Not measurable in field due to
24V Clock
Output
Not measurable
Drives Stapler Unit to rear at a high
speed (2700pps). If End Wall Open
Sensor doesn't sense any, no out-
put is allowed. (250 pulses).
Note: Not measurable in field due to
24V Clock
Output
Not measurable
Drives Stapler Unit to rear at a low
speed (2000pps). If End Wall Open
Sensor doesn't sense any, no out-
put is allowed. (250 pulses).
Note: Not measurable in field due to
24V Clock
Output
Low: On
Switches MBX Gate for SCT.
(150ms)