Of 10-6 Fuser Out Of Oil Rap - Xerox DocuColor 12/DCCS50 Service Manual

Table of Contents

Advertisement

OF 10-6 Fuser Out of Oil Rap

The purpose of this RAP is to resolve problems where the machine runs out of Fuser Oil with-
out declaring a Low Oil or Out of Oil fault.
NOTE: to decrease the interval between detection of low oil level and fault declaration change
NVM location 777-056 to 500, and location 777-058 to 3.
Procedure
Enter dC330 010-222 Oil Empty Sensor. Press Start. The Oil Empty Sensor status is L.
Y
N
Perform the following steps
1.
Open the Front Door and pull out the Drawer Assembly.
2.
Remove the Fuser Top Cover
3.
Slide the Fuser back in position. Latch the Drawer Assembly
4.
Remove the Oil Empty Sensor from the Oil Tank
sor, but do not disconnect it or reinstall it.
5.
Install a cheater in the Front Door Interlock, and allow the machine to come to
Ready.
The UI displays "Replace the Fuser Oil Cartridge soon."
Y
N
There is +5 VDC between
P/J167
Y
N
Go to
Flag 2
on BSD 10.5 (2 of 2) and troubleshoot the +5V circuit.
Go to
Flag 1
on BSD 10.5 (2 of 2) and check the wire between P/J167-2 on the Oil
Empty Sensor and P/J413A-3 on the IOT Drive PWB for an open circuit or a short
circuit to a voltage source. If the wire is OK, replace the Oil Empty Sensor
the problem continues, replace the IOT Drive PWB
Reinstall the Sensor. Make Sure that the green circuit pwb faces AWAY from the Heat
Lamps. Close the Front Door. If the "Replace the Fuser Oil Cartridge soon" message
remains, check for a loose connection at P/J167or P/J413A. If the harness is good,
replace the Oil Empty Sensor
(PL
8.7).
Replace the IOT Drive PWB
(PL
9.2).
Reissue
DocuColor 12/DCCS50
(PL
8.2) and Front Cover
(PL
8.1).
(PL
8.7). Thoroughly clean the sen-
pins 1 and 3.
(PL
9.2).
(PL
8.7). If
1/05
2-183
Status Indicator RAPs
OF 10-6 Fuser Out of Oil Rap

Advertisement