10-900 Fuser Cycle Down RAP

The Fuser temperature fell below the normal value during the job. The machine cycled down
and temporarily stopped the copying job; and when it reached the operating temperature, can-
celed the above condition and started again automatically (the job resumes).
NOTE: This condition should be expected to happen occasionally, especially when running a
long job. (No recovery steps are necessary.) If this condition occurs frequently, continue with
this RAP.
Initial Actions
Refer to BSD 10.2, 10.3 and 10.12 for the following procedure.
Ensure that the External Heat Roll Retract Sensor
Procedure
Close the Drawer. Cheat the Front Door Interlock. Switch on the power. The Heat Roll Heater
Rod illuminates after self-test completes.
Y
N
Go to the
OF10-3 Heat Roll AC Power
Enter dC330 010-031 Pressure Roll Heater Rod On. Press Start. The Pressure Roll Heater
Rod illuminates momentarily.
Y
N
Go to the
OF10-4 Pressure Roll AC Power
Enter dC330 010-029 External Heat Roll Lamp. Press Start. ACH is measured momen-
tarily between P/J100-1 on the SSR and P/J15-1 on the AC Driver PWB (ACN into AC
Driver PWB).
Y
N
Go to the
OF10-5 External Heat Roll AC Power
Open the drawer. Remove the cheater on the Front Door Interlock. Measure the resistance
across the External Heat Roll Heater Rod ( P/J193-1 to P/J196-1). The resistance is less
than 10 Ohms.
Y
N
Replace the External Heat Roll Heater Rod
Measure the resistance across the External Heat Roll Thermostat. The resistance is less
than 10 Ohms.
Y
N
Replace the External Heat Roll Thermostat
Check the following:
Disconnect the connectors to the Heat Roll, Pressure Roll, and External Heat Roll Ther-
mostats; AC Driver PWB; SSR; and the IOT Drive PWB. Check for broken, bent, or dirty
pins. Disconnect/reconnect the connectors several times to remove oxidation.
Check the Heat Roll Control Thermistor
8.6), or External Heat Roll Control Thermistor
If no problem is found with the connectors, replace the SSR
If the problem continues, replace the IOT Drive PWB
Status Indicator RAPs
10-900 Fuser Cycle Down RAP, OF10-1 OCT Detec-
(PL
8.4) is fully seated.
RAP.
RAP.
RAP.
(PL
8.8).
(PL
8.8).
(PL
8.4), Pressure Roll Control Thermistor
(PL
8.8). Replace if worn, or dirty.
(PL
9.3).
(PL
9.2).

OF10-1 OCT Detection Failure RAP

The system does not detect an OCT when one is installed.
Initial Actions
Refer to BSD 10.11 for the following procedure.
Procedure
Enter dC330
010-296 OCT
Detect. The display indicates L.
Y
N
Go to
Flag 7
and
Flag 8
ness is good, replace the IOT Drive PWB
Replace the IOT Drive PWB
(PL
(PL
1/05
2-178
manuals4you.com
manuals4you.com
on BSD 10.11. Check the harness for an open circuit. If the har-
(PL
9.2).
9.2).
Reissue
DocuColor 12/DCCS50