11-192 Paper Remains At Oct Exit Sensor Rap; 11-193 Decurler Exit Sensor Static Jam Rap - Xerox DocuColor 12/DCCS50 Service Manual

Table of Contents

Advertisement

11-192 Paper Remains at OCT Exit Sensor RAP

The Control Logic detected that paper remained on the Oct Exit Sensor at power on.
NOTE: If this machine has a Finisher/Sorter Accessory, go to Section 8D,
Remains at SCT Exit Sensor RAP
to troubleshoot this Fault Code.
NOTE: Ensure that Sorter S-1 Tag is installed.
Initial Actions
Refer to BSD11.4 for the following procedure.
Ensure that no paper is blocking the OCT Exit sensor and the sensor actuator moves
freely.
Check for excessive static on copies.
Check for any obstructions in the paper path.
Ensure that
P/J562
on the Mail Box Control PWB, and
are connected before beginning this RAP.
Procedure
Enter dC330 011-107 OCT Exit Sensor. Press Start. The display is L.
Y
N
Go to
Flag 2
on BSD 11.4 and check the harness for a short circuit. If the harness is good,
replace the OCT Exit Sensor
(PL
Control PWB
(PL
13.10).
More than +4.3 VDC is measured between P/J562-5 and GND on the Mail Box Control
PWB.
Y
N
Replace the OCT Exit Sensor
(PL
13.9).
Check the OCT Exit Sensor for intermittent operation. If the sensor is good, Replace the Mail
Box Control PWB
(PL
13.10).
Reissue
DocuColor 12/DCCS50
11-192 Paper
P/J567
on the V-Tra In Sensor
13.9).If the problem continues, replace the Mail Box

11-193 Decurler Exit Sensor Static Jam RAP

The Control Logic detected that paper remained on the Decurler Exit Sensor at power on.
NOTE: If this machine has a Finisher/Sorter Accessory, go to Section 8D,
Sensor Static Jam RAP
to troubleshoot this Fault Code.
NOTE: Ensure that Sorter S-1 Tag is installed.
Initial Actions
Refer to BSD11.3 for the following procedure.
Ensure that no paper is blocking the Decurler Exit sensor
Ensure that
P/J570
on the Mail Box Control PWB, Double Plug J571,
J654
on the Decurler Control PWB, and
nected before beginning this RAP.
Procedure
Enter dC330 011-145 Decurler Exit Sensor. Press Start. The display is H.
Y
N
Go to
Flag 1
on BSD 11.3 and check the harness for a short circuit. If the harness is good,
replace the Decurler Exit Sensor
Box Control PWB
(PL
13.10).
More than +4.3 VDC is measured between P/J654-2 and GND on the Decurler Control
PWB.
Y
N
Replace the Decurler Exit Sensor
Check the Decurler Exit Sensor for intermittent operation. If the sensor is good, Replace the
Mail Box Control PWB
(PL
13.10).
1/05
11-192 Paper Remains at OCT Exit Sensor RAP, 11-
2-201
11-193 Decurler Exit
P/J651
P/J658
on the Decurler Exit Sensor are con-
(PL
13.12). If the problem continues, replace the Mail
(PL
13.12).