775-852 ADC change by ATC (M)
775-853 ADC change by ATC (C)
7.
Go to dC131 NVM R/W:
Record the value in location 990-302 (v7.06.3 software only)
Record the value in location 759-039 (v7.06.3 software only)
If IOT software v11.50.3 is loaded, set NVM location 752-017 to 0.
If a Foreign Interface was enabled, record the value in NVM location 759-015, then
set location 752-002 to 0.
DO NOT use the Select All button to perform a complete NVM Initialization! If a full initializa-
tion is indicated, reset each area one-at-a-time, in the following sequence:
IISS
POST IPS
IOSS
Sys
UI
Sys (again)
8.
Select dC301 NVM Initialize.
9.
Select the appropriate area(s) to be initialized.
tialized with each area selection.
Table 1 NVM Initialization
Name
Description
IISS (PreIPS)
The following NVM will be initial-
ized.
a.
IIT NVM: Chain710 (All)
b.
IIT NVM: Chain715 (All)
c.
IIT NVM: Chain719 (All)
POST IPS
The following NVM will be initial-
ized.
a.
IPS NVM:Chain730-001-169
Reissue
DocuColor 12/DCCS50
CAUTION
Table 1
lists the NVM locations that are ini-
Remarks
Default: See dC131.
a.
Default: See dC131.
a.
Table 1 NVM Initialization
Name
Description
IOT (IOSS)
The following NVM will be initial-
ized.
a.
ROS NVM: Chain720 (All)
b.
PH NVM: Chain740, 749,
760, 761 (All)
c.
Marking NVM: Chain770 (All
except 087-100)
d.
IBT NVM: Chain771 (All)
e.
Drive NVM: Chain772 (All)
f.
Procon NVM: Chain773,
774, 775, 779 (All)
g.
Deve NVM: Chain776 (All)
h.
Fuser NVM: Chain777 (All)
i.
SorterNVM: Chain780 (All)
j.
Billing NVM: Chain990: 037,
293, 294, 295, 296, 297,
298, 299, 300, 301, 302
SYS
a.
SYS NVM: Chain752 (All
except the following codes)
(752-001-016)
b.
SYS NVM: Chain759 (All
except the following codes)
(759-130-150)
UI
The following NVM will be initial-
ized:
a.
UI NVM: Chain700 (All)
b.
UI NVM: Chain702 (All)
c.
UI NVM: Chain850 (1-006)
10. After all initializations are complete, go to dC131 NVM R/W. Re-enter the values for those
locations (759-015, 759-039, and/or 990-302) that were saved in step 7.
11. If NVM was successfully saved in step 5, go to dC351 and select Restore Machine Set-
tings. If NVM was not successfully saved, use the date a from step 2 and step 6 to man-
ually restore NVM.
12. Re-enter the values in the following tables even if the display indicates that the values are
already correct.
1/05
6-97
Remarks
Default: See dC131.
a.
Default: See dC131.
a.
Default: See dC131. Chain802 is
not initialized.
a.
General Procedures
dC301 NVM Initialization