Xerox DocuColor 12/DCCS50 Service Manual page 746

Table of Contents

Advertisement

Table 1 PH NVM List (761)
Chain-
Link
Name
Default
761-239 ARRIVE AT REGI
0
SENSOR 9(USED
TRAY 2)
761-240 ARRIVE AT REGI
0
SENSOR 10(USED
TRAY 2)
761-241 ARRIVE AT REGI
0
SENSOR 1(USED
TRAY 3)
761-242 ARRIVE AT REGI
0
SENSOR 2(USED
TRAY 3)
General Procedures
dC131PH NVM List (761)
Range
Description
None
#2 Tray: Measurement result - Registra-
tion Sensor ON timing after Feed start.
Theoretical value=607ms
JAM TIMER=556-656ms (50PPM,
12.5PPM B side), 536-676ms
(Other)
Unit=0.5ms/step (Normal paper),
0.8458ms/step (This paper 1)
Last storage location - see 761-364.
None
#2 Tray: Measurement result - Registra-
tion Sensor ON timing after Feed start.
Theoretical value=607ms
JAM TIMER=556-656ms (50PPM,
12.5PPM B side), 536-676ms
(Other)
Unit=0.5ms/step (Normal paper),
0.8458ms/step (This paper 1)
Last storage location - see 761-364.
None
#3 Tray: Measurement result - Registra-
tion Sensor ON timing after Feed start.
Theoretical value=807ms
JAM TIMER=756-856ms (50PPM,
12.5PPM B side), 736-876ms
(Other)
Unit=0.5ms/step (Normal paper),
0.8458ms/step (This paper 1)
Last storage location - see 761-365.
None
#3 Tray: Measurement result - Registra-
tion Sensor ON timing after Feed start.
Theoretical value=807ms
JAM TIMER=756-856ms (50PPM,
12.5PPM B side), 736-876ms
(Other)
Unit=0.5ms/step (Normal paper),
0.8458ms/step (This paper 1)
Last storage location - see 761-365.
Chain-
Link
Name
761-243 ARRIVE AT REGI
SENSOR 3(USED
TRAY 3)
761-244 ARRIVE AT REGI
SENSOR 4(USED
TRAY 3)
761-245 ARRIVE AT REGI
SENSOR 5(USED
TRAY 3)
761-246 ARRIVE AT REGI
SENSOR 6(USED
TRAY 3)
1/05
6-66
manuals4you.com
manuals4you.com
Table 1 PH NVM List (761)
Default
Range
Description
0
None
#3 Tray: Measurement result - Registra-
tion Sensor ON timing after Feed start.
Theoretical value=807ms
JAM TIMER=756-856ms (50PPM,
12.5PPM B side), 736-876ms
(Other)
Unit=0.5ms/step (Normal paper),
0.8458ms/step (This paper 1)
Last storage location - see 761-365.
0
None
#3 Tray: Measurement result - Registra-
tion Sensor ON timing after Feed start.
Theoretical value=807ms
JAM TIMER=756-856ms (50PPM,
12.5PPM B side), 736-876ms
(Other)
Unit=0.5ms/step (Normal paper),
0.8458ms/step (This paper 1)
Last storage location - see 761-365.
0
None
#3 Tray: Measurement result - Registra-
tion Sensor ON timing after Feed start.
Theoretical value=807ms
JAM TIMER=756-856ms (50PPM,
12.5PPM B side), 736-876ms
(Other)
Unit=0.5ms/step (Normal paper),
0.8458ms/step (This paper 1)
Last storage location - see 761-365.
0
None
#3 Tray: Measurement result - Registra-
tion Sensor ON timing after Feed start.
Theoretical value=807ms
JAM TIMER=756-856ms (50PPM,
12.5PPM B side), 736-876ms
(Other)
Unit=0.5ms/step (Normal paper),
0.8458ms/step (This paper 1)
Last storage location - see 761-365.
DocuColor 12/DCCS50
Reissue

Advertisement