Dc131Ph Nvm List (761) - Xerox DocuColor 12/DCCS50 Service Manual

Table of Contents

Advertisement

dC131PH NVM List (761)

Table 1 PH NVM List (761)
Chain-
Link
Name
Default
761-001 PRE FEED START
590
TIMING-TRAY1
761-002 PRE FEED START
559
TIMING-
TRAY1(PANEL B)
761-003 DOUBLE PRE
559
FEED START TIM-
ING-TRAY1
761-004 PRE FEED START
710
TIMING-TRAY2
761-005 PRE FEED START
679
TIMING-
TRAY2(PANEL B)
761-006 PRE FEED START
810
TIMING-TRAY3
Reissue
DocuColor 12/DCCS50
Range
Description
565-615 #1 Tray: Time from Pre-Feed Start to
Regi-Feed (Except B side)
Default=1180ms
Range=±50ms (±25)
Unit=2ms/step
534-624 #1 Tray: Time from Pre-Feed Start to
Regi-Feed (B side feed length: Less than
190mm (*))
Default=1118ms
Range=±50ms (±25)
Unit=2ms/step
Default DATA=559 (Quadrant
Machine CLOCK)
(*) Applied in the Nudger Roll 2-Drops
Mode
534-624 #1 Tray: Time from Pre-Feed Start to
Regi-Feed (B side feed length: 190 mm or
longer (*))
Default=1118ms
Range=±50ms (±25)
Unit=2ms/step
(*) Applied in the Double Pre Feed Mode.
685-735 #2 Tray: Time from Pre-Feed start to
Regi-Feed (Except B side)
Default=1420ms
Range=±50ms (±25)
Unit=2ms/step
654-704 #2 Tray: Time from Pre-Feed start to
Regi-Feed (B side)
Default=1358ms
Range=±50ms (±25)
Unit=2ms/step
785-835 #3 Tray: Time from Pre-Feed start to
Regi-Feed (Except B side)
Default=1620ms
Range=±50ms (±25)
Unit=2ms/step
Table 1 PH NVM List (761)
Chain-
Link
Name
Default
761-007 PRE FEED START
779
TIMING-
TRAY3(PANEL B)
761-008 PRE FEED START
910
TIMING-TRAY4
761-009 PRE FEED START
879
TIMING-
TRAY4(PANEL B)
761-010 TRAY1 NUDGER
39
ROLL SOLENOID
ON TIME
761-011 TRAY2 NUDGER
39
ROLL SOLENOID
ON TIME
761-012 TRAY3 NUDGER
39
ROLL SOLENOID
ON TIME
761-013 TRAY4 NUDGER
39
ROLL SOLENOID
ON TIME
761-014 ADJUST TRAY 1
24
PRE FEED STOP
POSITION(FEED
ROLL 1 SPEED
300mm/s)
1/05
6-47
Range
Description
754-804 #3 Tray: Time from Pre-Feed start to
Regi-Feed (B side)
Default=1558ms
Range=±50ms (±25)
Unit=2ms/step
885-935 #4 Tray: Time from Pre-Feed start to
Regi-Feed (Except B side)
Default=1820ms
Range=±50ms (±25)
Unit=2ms/step
854-904 #4 Tray: Time from Pre-Feed start to
Regi-Feed (B side)
Default=1758ms
Range=±50ms (±25)
Unit=2ms/step
0-45
#1 Tray Pre-Feed: Nudger Roll SOL ON
time
Default=390ms
Range=0-450ms (0 - 45)
Unit=10ms/step
Default DATA=39 (10ms RTMR)
0-45
#2 Tray Pre-Feed: Nudger Roll SOL ON
time
Default=390ms
Range=0-450ms (0-45)
Unit=10ms/step
Default DATA=39 (10ms RTMR)
0-45
#3 Tray Pre-Feed: Nudger Roll SOL ON
time
Unit=10ms/step
Default DATA=39 (10ms RTMR)
0-45
#4 Tray Pre-Feed: Nudger Roll SOL ON
time
Unit=10ms/step
Default DATA=39 (10ms RTMR)
4-39
Time from #1 Feed Out SNR ON to #1
Feed Motor OFF (Feed Roll 300mm/s -
Stop timing)
Default=48ms
Range=8-78ms (4-39)
Unit=2ms/step
Default DATA=24 (2ms RTMR)
General Procedures