10-370 Power On Pressure Roll Not Ready RAP

The Pressure Roll did not reach the Ready temperature within 8 minutes after Power On.
Initial Actions
Refer to BSD 10.2 and 10.12 for the following procedure.
Procedure
Cheat the Front Door Interlock. Switch on the power. Enter dC330 010-031 Pressure Roll
Heater Rod On. Press Start. The Pressure Roll Heater Rod illuminates momentarily.
Y
N
Go to the
OF10-4 Pressure Roll AC Power
Switch off the power. Cheat the Front Door Interlock Switch. Disconnect
Drive PWB. Check the resistance between J413- A13 and J413-A9 of the harness. The resis-
tance should be in the range of 0.78K ohms when the Heat Roll is hot, to 150K ohms when
cool (room temperature). The resistance is within specification.
Y
N
Disconnect
P/J173
on the Pressure Roll Control Thermistor. The resistance should be in
the range of 0.78K ohms when the Roll is hot, to 150K ohms when cool (room tempera-
ture). The resistance is within specification.
Y
N
Replace the P/R Control Thermistor
Go to
Flag 1
and
Flag 4
of BSD 10.2. Check for a loose wire or connector, or an intermit-
tent short circuit to ground.
Check the following:
Check the P/R Control Thermistor for cleanliness, damage and excessive wear at the
point where the Thermistor contacts the Pressure Roll. Ensure that it is installed correctly.
If the surface of the Thermistor is worn, replace the P/R Control Thermistor
Inspect the surface of the Pressure Roll for excessive wear due to the Thermistor.
Replace the Pressure Roll if necessary
If the problem continues, replace the P/R Control Thermistor
replace the IOT Drive PWB
(PL
9.2).
Reissue
DocuColor 12/DCCS50
RAP.
P/J413A
from the IOT
(PL
8.6).
(PL
(PL
8.3).
(PL
8.6). If the fault persists,

10-371 Stand By Pressure Roll Not Ready RAP

The Pressure Roll Heater Rod was On continuously for 90 seconds during the Standby Mode,
but the Pressure Roll did not reach operating temperature.
Initial Actions
Refer to BSD 10.2 and 10.12 for the following procedure.
Procedure
Cheat the Front Door Interlock. Switch on the power. Enter dC330 010-031 Pressure Roll
Heater Rod On. Press Start. The Pressure Roll Heater Rod illuminates momentarily.
Y
N
Go to the
OF10-4 Pressure Roll AC Power
Switch off the power. Cheat the Front Door Interlock Switch. Disconnect
Drive PWB. Check the resistance between J413- A13 and J413-A9 of the harness. The resis-
tance should be in the range of 0.78K ohms when the Heat Roll is hot, to 150K ohms when
cool (room temperature). The resistance is within specification.
Y
N
Disconnect
P/J173
the range of 0.78K ohms when the Roll is hot, to 150K ohms when cool (room tempera-
ture). The resistance is within specification.
Y
N
Replace the P/R Control Thermistor
Go to
Flag 1
and
Flag 4
tent short circuit to ground.
Check the following:
Check the P/R Control Thermistor for cleanliness, damage and excessive wear at the
point where the Thermistor contacts the Pressure Roll. Ensure that it is installed correctly.
8.6).
If the surface of the Thermistor is worn, replace the P/R Control Thermistor
Inspect the surface of the Pressure Roll for excessive wear due to the Thermistor.
Replace the Pressure Roll if necessary
If the problem continues, replace the P/R Control Thermistor
replace the IOT Drive PWB
1/05
10-370 Power On Pressure Roll Not Ready RAP, 10-
2-163
RAP.
on the Pressure Roll Control Thermistor. The resistance should be in
(PL
8.6).
of BSD 10.2. Check for a loose wire or connector, or an intermit-
(PL
8.3).
(PL
(PL
9.2).
P/J413A
from the IOT
(PL
8.6).
8.6). If the fault persists,