REP 6.1.4 Bias Brush

Parts List on
PL 6.1
Removal
Turn power off and disconnect the power plug.
1.
Remove the following parts:
a.
Cover Assembly
(PL 6.5 Item
b.
Trickle Toner Bottle
(PL 6.5 Item
2.
Remove the Drum Unit
(REP
5.3.1).
3.
Remove the Bias Brush
(Figure
1).
1. Remove the screws (2).
2. Remove the fasten terminal.
3. Remove the Bias Brush.
Figure 1 Remove the Bias Brush
Repairs and Adjustments
REP 6.1.4
WARNING
18)
23)
Installation
NOTE: Make sure that the protruding part of the Bias Brush is in the frame hole
1.
Reinstall the parts in the reverse order of disassembly.
1/05
4-82
manuals4you.com
manuals4you.com
Figure 2 Reassembly
DocuColor 12/DCCS50
(Figure
2).