7.2.1.2.11 speed-duplex

Command: speed-duplex {auto | force10-half | force10-full | force100-half | force100-full |
{ {force1g-half | force1g-full} [nonegotiate [master | slave]] } }
no speed-duplex
Function: Sets the speed and duplex mode for 1000Base-TX or 100Base-TX ports; the "no
speed-duplex" command restores the default speed and duplex mode setting, i.e., auto speed
negotiation and duplex.
Parameters: auto for auto speed negotiation; force10-half for forced 10Mbps at half-duplex;
force10-full for forced 10Mbps at full-duplex mode; force100-half for forced 100Mbps at
half-duplex mode; force100-full for forced 100Mbps at full-duplex mode; force1g-half for forced
1000Mbps at half-duplex mode; force1g-full for forced 1000Mbps at full-duplex mode;
nonegotiate for disable auto-negotiation for 1000 Mb port; master to force the 1000Mb port to be
master mode; slave to force the 1000Mb port to be slave mode.
Command mode: Port configuration Mode
Default: Auto-negotiation for speed and duplex mode is set by default.
Usage Guide: This command applies to 1000Base-TX or 100Base-TX ports only. speed-duplex
command is not available for 1000Base-X port. For combo port, this command applies to the
1000Base-TX port only and has no effect on 1000Base-X port. To change the negotiation mode of
1000Base-X port, use negotiation command instead.
When configuring port speed and duplex mode, the speed and duplex mode must be the same as the
setting of the remote end, i.e., if the remote device is set to auto-negotiation, then auto-negotiation
should be set at the local port. If the remote end is in forced mode, the same should be set in the
local end.
1000Gb ports are by default master when configuring nonegotiate mode. If one end is set to
master mode, the other end must be set to slave mode. force1g-half Is not supported yet.
Example: Port 1 of Switch 1 is connected to port 1 of Switch2, the following will set both ports in
forced 100Mbps at half-duplex mode.
Switch1(Config)#interface e1/1
Switch1(Config-Ethernet1/1)#speed-duplex force100-half
Switch2(Config)#interface e1/1
Switch2(Config-Ethernet1/1)#speed-duplex force100-half

7.2.2 VLAN Interface Configuration

7.2.2.1 VLAN Interface Configuration Task Sequence

1.
Enter VLAN Mode
2.
Configure the IP address for VLAN interface and enable VLAN interface.
1. Enter VLAN Mode
EES4710BD 10 Slots L2/L3/L4 Chassis Switch