2.3.3 Position and function of the heating elements

Heater element
Pre-heater (Heater A)
Fixer (Heater B)
Post-Fixer (Heater C)
Dryer (Heater D)
There have been a number of requests from the field, asking the heaters to be on by default for a few user
settings. This has now been implemented as follows:
For user 1 and user 8 default settings are as follows:
Pre heater A:
Fixer B:
Post Fixer C:
Dryer D:
For users 2
7, by default the heaters are still OFF.
Notes
Please note some RIP software do not allow selection of the user from software side. In some cases,
however, they do automatically activate user 8.
AP-75036 - Revision 1.3 – 20/03/06
Temperature
20 – 50°C
20 – 40°C
20 – 70°C
20 – 50°C
50°C
40°C
50°C
50°C
Open the pores to make the media more receptive for Océ
IJC910 Low Solvent Ink.
To establish optimum fixation onto the media (coated and
uncoated).
Optimizes the dot gain control.
The post-fixer finalizes the fixation process and helps to make
the prints touch-dry.
The dryer completes the drying for compatibility with the take-
up in combination with higher output speeds.
Stickiness of printed banner materials is improved.