Setting the Input/Output Conditions

17-5 Computer link

When "PC-LINK" has been specified in item "3SERIAL OUTPUT" on the [I/O CONDITIONS] menu
(page 17-1), the computer link conditions must be set on the [COMPUTER LINK] menu.
On the [SYSTEM COND] menu, move the cursor to item "3 COMPUTER LINK" and press the SET key.
See Chapter 17 "Computer Link" for applicable models made by these manufacturers.
Note 1: Use an even address as the write start address.
Note 2: When 512 bytes are used for a write register on a Sharp model, select a write start address
from the following addresses.
09000, 19000, 29000, 39000, 49000, 59000, 69000, 79000, 89000 , 99000
17
[SYSTEM COND]
1I/O CONDITIONS
(TO NEXT SUB-MENU)
2COMM. SET
(TO NEXT SUB-MENU)
3CONPUTER LINK
(TO NEXT SUB-MENU)
[COMPUTER LINK]
1PC MANUFACTURER SHARP(COMM.PORT LINK-MDL) MITSUBISHI OMRON
2STATION NO.
01
3WRITE TOP ADRS
09000
4CONTROL PROC.
FORM1 FORM4
5BLK WRT COMMAND WW QW
OPS-MENU RETURN LOCK
Display when only "MITSUBISHI" is specified on "
Menu
Select either FORM 1 or 4 for the control procedure.
4 CONTROL
FORM 1
PROC.
FORM 4
- In version 2.01, only "FORM 1" was available.
Select either WW or QW for the block write command.
5 BLK WRT
WW
COMMAND
QW
- In version 2.01, only "WW" was available.
If "SHARP" or "OMRON" is selected, items 4 and 5 will not be displayed.
Item
- Sharp: 00 to 37
Station No.
- Mitsubishi: 00 to 31
- OMRON: 00 to 31
- Sharp: 09000 to 99776
Write address
- Mitsubishi: D0000 to D9999
(max. 512 bytes)
- OMRON: DM0000 to DM9999
* In this book, octal notation is indicated by adding
1
PC MANUFACTURER" item.
Setting details
No line terminator
With line terminators: "CR" + "LF"
Data writing address range: D0000 to D1023
Data writing address range: D000000 to D008191
17-20
Setting range
*
(8)
(8)