Sharp IV-S30 User Manual page 175

Compact image sensor camera function and operation
Table of Contents

Advertisement

Continued from the previous page
(5) Operations on the [FINAL OUTPUT COND] menu
1. On the [TYPE MEAS COND] menu, press the ESC key twice and move the cursor to the "FINAL-
OUTPUT" item using the up/down and left/right keys. Then press the SET key.
- The [FINAL OUTPUT COND] menu will be displayed.
2. Move the cursor to the "1PAGE NO." item using the up and down keys, and press the SET key. Select
"YES" using the left and right keys, and press the SET key.
- Items 2 to 5 will be displayed.
[FINAL OUTPUT COND]
2
1PAGE NO.
0(0~7) NO YES
2SET POSITION
MOVE
3INPUT SIGNAL
3
AUX-RLY C000(0~127) EXT-INP X0(0~7)
4
TMR TM0(0~7)
AN00(0~15)
4LOGIC SYMBOL
5OUTPUT SIGNAL
OUT Y00(0~15)
5
TMR TM0(0~7)
CNTR CN0(0~7)
DEL
OPS-MENU RETURN LOCK
6
[PAGE0]
0
1
2
INPUT0
LOGIC
INPUT1
LOGIC
INPUT2
LOGIC
INPUT3
LOGIC
3. Move the cursor to the "2SET POSITION" item using the up and down keys, and press the SET key.
- Move the cursor to the leftmost column of the INPUT 0 logic settings using the up/down and left/right
keys, and press the SET key.
4. Move the cursor to the "3INPUT SIGNAL" item using the up and down keys, and press the SET key.
- Move the cursor to "AUX-RLY C000(0 - 127)" using the left and right keys, and select "C000" using the
left/right (change digits) and up/down keys. Then press the SET key.
- The following logical symbol will be displayed in the leftmost column of INPUT 0.
[PAGE0]
INPUT0
LOGIC
5. Move the cursor to the "5OUTPUT SIGNAL" item using the up and down keys, and press the SET key.
- Move the cursor to "OUT Y00(0 - 15)" using the left and right keys, and specify "Y00" using the up and
down keys. Then press the SET key.
- The output coil for INPUT 0 will be displayed.
[PAGE0]
INPUT0
LOGIC
6. Move the cursor to the "OPS-MENU" item using the up and down keys, and press the SET key.
- The screen will return to the MAIN OPS MENU.
To the next page
2
4
CNTR CN0(0~7)
OUT Y00(0~15)
DEL
AUX-RLY C000(0~127)
SET-VL000(000~999)
SET-VL000(000~999)
3
4
5
6
7
OUT
15-15
Numerical Calculations
OUTPUT
OUTPUT
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iv-s31mIv-s32mIv-s33m

Table of Contents