Sharp IV-S30 User Manual page 173

Compact image sensor camera function and operation
Table of Contents

Advertisement

Continued from the previous page
3. Move the cursor to the "3FORMULA" item using the up and down keys, and press the SET key.
- Move the cursor to "REG00(0 - 15)" using the left and right keys, and specify "REG01" using the up and
down keys.
- Move the cursor to "MDL0(0 - 1)" using the left and right keys, and specify "MDL0" using the up and down
keys. Then press the SET key.
- 01X0 will be displayed in the formula field.
X
01X0 refers to the X coordinate of the detection point in model 0, stored in register No.01 (image 1).
- Move the cursor to "-" using the left and right keys, and press the SET key.
- A dash "-" will be displayed in the formula field.
- Move the cursor to "REG01(0 - 15)" using the left and right keys, and specify "REG00" using the up and
down keys.
- Move the cursor to "MDL0(0 - 1)" using the left and right keys, and press the SET key.
- 00X0 will be displayed in the formula field.
X
00X0 refers to the X coordinate of the detection point in model 0, stored in register No.00 (image 0).
- Press the ESC key.
4. Move the cursor to the "5UPR&LOW LIMIT" item using the up and down keys, and press the SET key.
- Move the cursor to the upper limit using the left and right keys, and press the SET key. Select a digit using
the left and right keys. Enter the number +160.00 using the up and down keys, and press the SET key.
5UPR&LOW LIMIT +0000000.0000~+0000160.0000
- Move the cursor to the lower limit using the left and right keys, and press the SET key. Select a digit using
the left and right keys. Enter the number +140.00 using the up and down keys, and press the SET key.
5UPR&LOW LIMIT +0000140.0000~+0000160.0000
- +0000140.00 to +0000160.00 will be displayed in the lower and upper limit fields.
- Press the ESC key.
5. Move the cursor to the "1CALC RESULT" item using the up and down keys, and press the SET key.
Specify "N01" using the up and down keys, and select "YES" using the left and right keys. Then press the
SET key.
- As described in steps 2 to 4, enter 01Y0 to 00Y0 in the formula field, and enter +0000090.00 to
+0000095.00 in the upper and lower limit fields.
X
Y
6. Move the cursor to the "7RUN A TEST" item using the up and down keys, and press the SET key.
- Press the SET key once more. Then the settings will be stored, and the test will be executed.
- The evaluation result (OK/NG) of the calculations will be displayed.
X
Y
OK: When the test result based on the calculations is within the specified range
NG: When the test result based on the calculations is outside of the specified range
7. Move the cursor to the "RETURN" item using the up/down and left/right keys, and press the SET key.
- The [TYPE MEAS COND] menu will be displayed.
To the next page
Upper limit
Lower limit
15-13
Numerical Calculations
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iv-s31mIv-s32mIv-s33m

Table of Contents