Continued from page 10-3 or 10-4
[EVALUATION COND]
1REGISTER NO. 0(0~3)
2CONDITION SET RESET AUTO(+10%)
3NUMBER OF OBJ000~128
4TOTAL AREA
000000~245760
5LABEL NO.
000(0~127)
6OBJECT AREA 000000~245760
CENT OF GRAV-X 000.0~511.0
CENT OF GRAV-Y 000.0~479.0
MAIN AXIS ANGL
FILLET WIDTH
PERIPHERAL
MID POINT
7TEST
EXEC(WITH-POSI.ADJ WITHOUT-POSI.ADJ)
OPS-MENU RETURN LOCK
Before setting the upper and lower limits between which the evaluation result is considered
acceptable, execute item "7TEST," and check the test results.
When you want to select a numeric calculation
- Select "RETURN" to return to the [MEAS COND] menu, and then select
"NUM-CALC" and press the SET key.
- See "Chapter 15: Numerical Calculations"
When you want to select a PC function
- Select "RETURN" to return to the [MEAS COND] menu, and then select
"OUT-COND" and press the SET key.
- See "Chapter 16: PC Function"
Return to the MAIN OPS MENU.
Pressing the TRG/BRT key will start a measurement manually.
[Display of the
measured results]
Final evaluation result
Measuring time
Measurement program number
Resistration number
in the measurement condition
NUMBER OF OBJECTS
TOTAL AREA
LABEL NUMBER
OBJECT AREA
CENTER OF GRAVITY
CORDINATE
MAIN AXIS ANGLE
FILLET DIA
PERIPHERAL
MID POINT
- CENT OF GRAV, MAIN AXIS
ANGL, FILLET WIDTH,
PERIPHERAL , or MID POINT
are displayed when
measurement of these
parameters has been specified
("YES" has been selected) on
the [MEAS COND] menu
(page 10-2).
[TEST RESULT]
[OUTPUT]
K=004
OK
NO
A=005200
OK
NO
R=000110
OK
NO
GX=100.0
OK
NO
GY=094.0
B=+110.0
FX=070
FY=062
CR=00217.0
CX=000.0
CY=000.0
Display example
(TYPE00)
OK
MEAS XXXXms 1999-08-01 10:30
MEASUREMENT 1 LABEL-BIN-OBJ
REGISTER N0(0~3)
K=004
OK
A=006168
OK
LABEL NO.000(000~007)
R=001542
OK
GX=206.0
OK
GY=303.0
B=042680
FX=042
FY=037
CR=00138.8
CX=
CY=
X0~7
Y0~7
CHG-MEA CHG-REG CHG-RST CHG-C1
OPS-CND MEA-CND SYS-CND CHG-TYPE NEXT-NG RE-EXAM-NG MANL-MEAS
10-5
Object Identification by Binary Conversion
- Page 3-16
- When "BINARY-IMG-MASK" is selected for
the window type, only register number 0 is
available. - See page 10-2.
You can set the output destinations
using the up and down keys.
(NO, Y0 to Y7, C000 to C127)
CENT OF GRAV, MAIN AXIS ANGL,
FILLET WIDTH, PERIPHERAL , or
MID POINT are displayed when
measurement of these parameters
has been specified ("YES" has been
selected) on the [MEAS COND]
menu (page 10-2).
READY
CHG-C2 CHG-EVAL CUSTOM-MNU
10
F.IMG C1 L