Setting the Input/Output Conditions
Time chart (when auto mode (edge) is selected for as the CCD sampling start)
CCD trigger
cycle
Serial
CCD trigger
window
(not highlighted)
READY output
(While measuring
or setting = L)
Terminate
measurement
(C119)
PC calculation
condition
Parallel output
(Y0 to Y7)
Note: Result output; The data in the block No., set in item "5SET SERIAL BLOCK" on the [OBJECT
TYPE I/O] menu, will be transmitted to the personal computer. - See page 17-21.
Time chart (when auto mode (level) is selected for as the CCD sampling start)
CCD trigger
cycle
Serial
CCD trigger
window
(not highlighted)
READY output
(While measuring
or setting = L)
17
Terminate
measurement
(C119)
PC calculation
condition
Parallel output
(Y0 to Y7)
Type
Black
White
Turn ON READY
signal by termination
Trigger
of result output.
P
P
P
P
Halt PC operation
during measurement
C
C
C
C
When the object type is changed,
all Y output and auxiliary relays turn OFF.
Type
Black
White
Trigger
P
P
P
P
Halt PC operation
C
C
C
C
during measurement
When the object type is changed,
all Y output and auxiliary relays
turn OFF.
Restarts CCD sampling automatically after
measurement is completed.
When a trigger signal is input during
sending object type change command,
this command will be invalid.
Result
Type
output
Black
White
Trigger
Measurement result is valid at the end of
a measurement
P
P
P
P
P
P
P
P
P
Halt PC operation
during measurement
C
C
C
C
C
C
C
C
C
Parallel output is valid for PC control after
the measurement result is determined.
Result output
Restarts CCD sampling automaticallyafter
measurement is completed.
When a trigger signal is input during
sending object type change command,
this command will be invalid.
Result
Type
output
Trigger
Measurement result is valid
at the end of a measurement
P
P
P
P
P
Halt PC operation
C
C
C
C
C
during measurement
Parallel output is valid for
PC control after the
measurement result is
determined.
Result output
17-16
Result
output
Black
P
P
P
P
C
C
C
C
Result output
Result
output
Black
Trigger
P
P
P
P
P
P
P
P
P
P
P
P
C
C
C
C
C
C
C
C
C
C
C
C
Result output
P
C
Whi-
te