(9) Measurement start input = CCD trigger, start sampling = auto, object type change, result
output = parallel
Setting order 1
[SYSTEM COND]
1I/O CONDITIONS (TO NEXT SUB-MENU)
2COMM.SET
(TO NEXT SUB-MENU)
[I/O CONDITIONS]
1MEAS INP I/F
PARALLEL+SERIAL CCD-TRIG
2START CCD SAMPLE AUTO(EDGE LEVL) PARALLEL SERIAL+USB
3OUTPUT OBJ TYPE PARALLEL SERIAL+USB
Setting "17-3 CCD trigger"
Time chart (when auto mode (edge) is selected for as the CCD sampling start)
CCD trigger
cycle
Type selection
input
Specified object type number
*
IV-S33M:
X1 to X6
CCD trigger
Black
window
(not highlighted)
Trigger
READY output
(While measuring
or setting = L)
Measurement result is valid
at the end of a measurement
PC calculation
P
P
P
condition
C
C
C
When the object type is changed, all Y
output and auxiliary relays turn OFF.
Parallel output
(Y0 to Y7)
2 (
3)
Select one of
the following.
Measurement is started when the CCD trigger level is ON.
Measurement is started when a CCD trigger signal is received.
Measurement
Restarts CCD sampling automatically after
measurement is completed.
White
P
Halt PC operation
during measurement
C
17-13
Setting the Input/Output Conditions
Configuration example
Camera 1 (image capturing + CCD trigger)
Camera 2 (image capturing)
Remote key pad
Controller
Power supply
(24 VDC)
Warning lamp
External output
(Y0 to Y7)
Black White
Work
CCD trigger
Edge
Level
Black
White
Black
Trigger
P
P
P
P
P
P
P
P
P
Halt PC operation
during measurement
C
C
C
C
C
C
C
C
C
Parallel output is valid for PC control after
the measurement result is determined.
Result output
Monitor
Start sampling input
X0
(photo sensor or
proximity sensor)
Type selection switch
-See page 17-4.
17
P
P
P
P
P
C
C
C
C
C
Result output