(4) Operations on the [OUTPUT COND] menu
1. On the [TYPE MEAS COND] menu, move the cursor to the "OUT-COND" item using the left and right keys,
and press the SET key.
- The [OUTPUT COND] menu will be displayed.
2. Move the cursor to the "1PAGE NO." item using the up and down keys, and press the SET key. Select
"YES" using the left and right keys, and press the SET key.
- Items 2 to 5 will be displayed.
[OUTPUT COND]
1PAGE NO.
2
2SET POSITION
3
3INPUT SIGNAL
4
4LOGIC SYMBOL
5
5OUTPUT SIGNAL
7
OPS-MENU RETURN LOCK
[PAGE0]
8
INPUT0
LOGIC
INPUT1
LOGIC
INPUT2
LOGIC
INPUT3
LOGIC
3. Move the cursor to the "2SET POSITION" item using the up and down keys, and press the SET key.
- Move the cursor to the leftmost column of the INPUT 0 logic settings using the up/down and left/right keys,
and press the SET key.
4. Move the cursor to the "3INPUT SIGNAL" item using the up and down keys, and press the SET key.
- Move the cursor to "CALC N00(0 - 15)" using the left and right keys, and specify "CAL N00" using the up
and down keys. Then press the SET key.
5. Move the cursor to the "4LOGIC SYMBOL" item using the up and down keys, and press the SET key.
- Move the cursor to "-||-" using the left and right keys, and press the SET key.
- The logical condition will be displayed in the leftmost column of the LOGIC row under INPUT 0.
- N00 refers to the N00 calculation result, that was entered on the [NUMERIC CALC] menu.
6. Move the cursor to the "2SET POSITION" item using the up and down keys, and press the SET key. Move
15
the cursor to the 1st column of the INPUT 0 logic settings using the left and right keys, and press the SET
key.
- As described in steps 4 and 5, enter "CALC N01" to be used as an input signal.
7. Move the cursor to the "5OUTPUT SIGNAL" item using the up and down keys, and press the SET key.
Press the SET key again.
- Specify "C000" for the auxiliary relay number using the left/right (change digits) and up/down keys, and
press the SET key.
- The output coil for INPUT 0 will be displayed.
8. Move the cursor to the "RETURN" item using the up/down and left/right keys, and press the SET key.
- The screen will return to the [TYPE MEAS COND] menu.
To the next page
0(0~4) NO YES
MOVE
2
REGISTER NO.00(0~15)
MATCH M0(0~1) CRD-X0(0~1) CRD-Y0(0~1)
LVL G0 (0~1)
CALC N00(0~15) AUX.RLY-C000(0~127)
AUX-RLY C000(0~127)
0
1
2
3
4
5
6
3
[PAGE0]
INPUT0
LOGIC
[PAGE0]
INPUT0
LOGIC
[PAGE0]
INPUT0
LOGIC
DEL
OUT
7