Sharp IV-S30 User Manual page 137

Compact image sensor camera function and operation
Table of Contents

Advertisement

Continued from the previous page (when WINDOW has been set to "NORMAL")
1REGISTER NO.
0(0~3)
2MEAS SHAPE
RECTANGLE CIRCLE ELLIPSE
3MEAS AREA
MOVE UP.L(224,208) LO.R(287,271)
4MASK NO.
0(0~3)
5MASK SHAPE
NO RECTANGLE CIRCLE ELLIPSE
6MASK AREA
MOVE UP.L(224,208) LO.R(287,271)
7AUTO REGIST
EXEC(L LIMIT ONLY U&L LIMITS)
8THRESHOLD
U.LM255 L.LM100(0~255)
9INVERT B/W
NO YES
0BINARY PROCESS
FIXED THRESHOLD-ADJ(VAR-DIFF VAR-RATE)
qBINRY NOISE FILT
NO EXPD.
wNUM. OF FILT PASS
EXPD.0 CONTR.0(0~5)
AREA FILTER
OPS-MENU RETURN LOCK EVALUATION
- Each time the ESC key is pressed, the menu screen will change to display all items or to
display individual items, one at a time.
- The data in item 3 varies according to the selection in item 2.
Selection in item 2 Data displayed in item 3
RECTANGLE
CIRCLE
ELLIPSE
- The data in item 6 varies according to the selection in item 5.
Selection in item 5 Data displayed in item 6
NO
RECTANGLE
CIRCLE
ELLIPSE
Ë Area settings
- To specify an area, the screen must be in the freeze image mode.
- The binary image display after changing screen from "freeze," then to "through," and finally back
to "freeze," will be a binary image of the object that was captured the first time the IV-S30 was in
the "freeze" mode.
The binary image that is captured in the "freeze" mode the third time can be displayed when you
specify items 2 to r in the settings.
Ë Mask area
The general area to be measured may contain an object that does not need to be measured. To
eliminate such an object from the measurements, a mask area is used.
Object to be measured
Ë Area filter
This function is used to eliminate objects if their measured area is outside of the upper and lower
limits.
Ë A registration example
Measurement area
(Rectangle)
Mask area
(Rectangle)
Select "EVALUATION" (or select "EVALUATION" on the [MEAS COND] menu) and press the SET key.
To page 10-5
CONTR. CONTR.
EXPD.
MOVE UP.L (224,208) LO.R (287,271)
CENTER (256,240) RAD. (032)
CENTER (256,240) RAD. (032,032)
No data displayed
MOVE UP.L (224,208) LO.R (287,271)
CENTER (256,240) RAD. (032)
CENTER (256,240) RAD. (032,032)
10-3
Object Identification by Binary Conversion
(Reference pages)
- Pages 3-4 to 3-6
- Page 3-8
- Page 3-9
- Page 3-11
- Page 3-8
Measurement area
Mask area
- The inside of the measurement area
(excluding the mask area) is converted to
binary data.