Input/output condition
7 'READY' ON

[2] When you want to select the "CCD-TRIG" on the "MEAS INP I/F" line.

On the MAIN OPS MENU, move the cursor to "SYS-CND," and press the SET key.
-On the [SYSTEM COND] menu, move the cursor to item "1I/O CONDITIONS"
and press the SET key.
-On the [I/O CONDITIONS] menu, move the cursor to "1 MEAS INP I/F" and
press the SET key. Then select "CCD-TRIG" and press the SET key.
AUTO(EDGE LEVL)"
[SYSTEM COND]
1I/O CONDITIONS
2COMM.SET
[I/O CONDITIONS]
PARALLEL"
1MEAS INP I/F
2START CCD SAMPLE AUTO(EDGE LEVL) PARALLEL SERIAL+USB
3SERIAL OUTPUT NO PC-LINK SERIAL
4MANL TYPE CHNG NO YES
5PARALLEL INP X6
6PARALLEL INP X7
7STROBE OUT
and press the SET key.
1MEAS INP I/F
2START CCD SAMPLE AUTO(EDGE LEVL) PARALLEL SERIAL+USB
3MANL TYPE CHNG NO YES
4PARALLEL INP X6
5PARALLEL INP X7
6STROBE OUT
The details of the individual items on the [I/O CONDITIONS] menu are the
same as described on pages 17-1 to 17-2.
The "64OBJ-CHG" is only displayed here when the IV-S33M is used. When the IV-
S31M/S32M is used, "EXT-INP" will be displayed here.
Set the time to turn ON the READY output signal.
(When the measurement start input source is set to parallel, the object type
change signal will also be parallel, and results will be output as parallel signals.
- See page 17-5.)
Æ At the end of an image capture
When the controller stops capturing the image, the READY signal turns ON.
Æ At the end of a measurement
When the controller stops measuring, the READY signal turns ON.
1
MEAS INP I/F
CCD-TRIG" and "
and press the SET key.
(TO NEXT SUB-MENU)
(TO NEXT SUB-MENU)
1MEAS INP I/F
PARALLEL+SERIAL CCD-TRIG
2START CCD SAMPLE AUTO(EDGE LEVL) PARALLEL SERIAL+USB
3OUTPUT OBJ TYPE PARALLEL SERIAL+USB
4MANL TYPE CHNG NO YES
5PARALLEL INP X6
64OBJ-CHG* REG REF(MEAS0 COMPARE-IMGS)
MODIFY-AREA-SIZE(00%) EXT-INP
6PARALLEL INP X7
EXT-INP CHNG-IMG-OUT-CAM CAM-MEAS 2 IMAGES
7STROBE OUT
NO Y0
OPS-MENU RETURN LOCK
1
MEAS INP I/F
CCD-TRIG" and "
and press the SET key.
PARALLEL+SERIAL CCD-TRIG
64OBJ-CHG* REG REF(MEAS0 COMPARE-IMGS)
MODIFY-AREA-SIZE(00%) EXT-INP
EXT-INP CHNG-IMG-OUT-CAM CAM-MEAS 2 IMAGES
NO Y0
1
MEAS INP I/F = CCD-TRIG" and "START CCD SAMPL = SERIAL + USB"
PARALLEL+SERIAL CCD-TRIG
64OBJ-CHG* REG REF(MEAS0 COMPARE-IMGS)
MODIFY-AREA-SIZE(00%) EXT-INP
EXT-INP CHNG-IMG-OUT-CAM CAM-MEAS 2 IMAGES
NO Y0
Setting the Input/Output Conditions
Setting details
2
START CCD SAMPLE
2
START CCD SAMPLE
17-3
After selecting
"REG-REF," change
0 to 4 using the
up/down keys.
Change
Y0 to Y7 using
the up/down keys.
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iv-s31mIv-s32mIv-s33m

Table of Contents