Sign In
Upload
Manuals
Brands
Fujitsu Manuals
Server
PRIMERGY BX924 S4
Fujitsu PRIMERGY BX924 S4 Manuals
Manuals and User Guides for Fujitsu PRIMERGY BX924 S4. We have
1
Fujitsu PRIMERGY BX924 S4 manual available for free PDF download: Upgrade And Maintenance Manual
Fujitsu PRIMERGY BX924 S4 Upgrade And Maintenance Manual (286 pages)
Server blade
Brand:
Fujitsu
| Category:
Server
| Size: 9.86 MB
Table of Contents
Server Blade
1
Copyright and Trademarks
2
Table of Contents
7
1 Introduction
17
Notational Conventions
18
2 Before You Start
19
Classification of Procedures
21
Upgrade and Repair Units (URU)
22
Field Replaceable Units (FRU)
23
Average Task Duration
24
Tools You Need at Hand
25
Documents You Need at Hand
26
3 Important Information
29
Safety Instructions
29
CE Conformity
36
FCC Class a Compliance Statement
37
Environmental Protection
38
4 Basic Hardware Procedures
41
Using Diagnostics Information
41
Accessing the Management Blade Web Interface
41
Locating the Defective Server Blade
43
Determining the Error Class
44
Global Error Indicator
45
Customer Self Service (CSS) Indicator
46
Locating the Defective Component
48
Opening the Rack Door
51
Opening the Rack Door of a PRIMECENTER Rack
51
Opening the Rack Door of a PRIMECENTER M1 Rack
51
Shutting down the Server Blade
52
Removing a Server Blade
53
Preliminary Steps
53
Removing the Server Blade from the System Unit
54
Opening the Server Blade
55
Closing the Server Blade
56
Installing the Server Blade in the System Unit
57
Switching on the Server Blade
60
Concluding Software Tasks
61
Closing the Rack Door
62
Closing the Rack Door of a PRIMECENTER Rack
62
Closing the Rack Door of a PRIMECENTER M1 Rack
62
5 Basic Software Procedures
63
Starting the Maintenance Task
63
Launching a Video Redirection to a Server Blade
63
Checking the Server Blade Status
63
Checking the Server Blade Status Via Management Blade Web Interface
63
Checking the Server Blade Status Via Irmc
64
Saving BIOS Settings
65
Saving Irmc Settings
65
Connecting Virtual Media to the Managed Server Blade
65
Disabling Bitlocker Functionality
66
Disabling Boot Watchdog Functionality
67
Viewing Boot Watchdog Settings
67
Configuring Boot Watchdog Settings
68
Verifying and Configuring the Backup Software Solution
69
Note on Server Maintenance in a Multipath I/O Environment
70
Switching on the ID Indicator
72
Completing the Maintenance Task
73
Updating or Recovering the System Board BIOS and Irmc
73
Updating or Recovering the System Board BIOS
73
Updating or Recovering the Irmc
76
Restoring BIOS Settings
78
Restoring Irmc Settings
78
Updating Mezzanine Card Firmware
78
Enabling Option ROM Scan
80
Verifying and Configuring the Backup Software Solution
81
Resetting the Boot Retry Counter
82
Viewing the Boot Retry Counter
82
Enabling Boot Watchdog Functionality
84
Enabling Replaced Components in the System BIOS
85
Verifying the Memory Mode
85
Verifying the System Time Settings
86
Viewing and Clearing the System Event Log (SEL)
87
Viewing the SEL
87
Saving the SEL
88
Clearing the SEL
89
Updating the NIC Configuration File in a Linux Environment
89
Enabling Bitlocker Functionality
91
Performing a RAID Array Rebuild
92
Looking up Changed MAC / WWN Addresses
92
Looking up MAC Addresses
92
Looking up WWN Addresses
93
Using the Chassis ID Prom Tool
94
Configuring LAN Teaming
94
After Replacing / Upgrading LAN/CNA Controllers
94
After Replacing the Server Blade
95
Switching off the ID Indicator
95
6 Hard Disk Drives / Solid State Drives
97
Basic Information
97
Overview of the Disk Mounting Kits
98
Installing HDD/SSD
99
Required Tools
99
Preliminary Steps
99
Locations of the Drives Inside the Server Blade
100
Installing SSD 0
101
Installing HDD/SSD 1
103
Concluding Steps
107
Removing HDD/SSD
108
Required Tools
108
Preliminary Steps
108
Removing SSD 0
109
Removing HDD/SSD 1
111
Concluding Steps
113
Replacing a HDD/SSD
114
Required Tools
114
Preliminary Steps
114
Removing a HDD/SSD 1
115
Installing a HDD/SSD 1
115
Concluding Steps
115
Replacing SAS / PCH Backplanes
116
Required Tools
116
Preliminary Steps
116
Removing the SAS / PCH Backplane
117
Installing the SAS / PCH Backplane
118
Concluding Steps
120
7 Mezzanine Cards
121
Basic Information
122
Installing Riser Cards
124
Removing Riser Cards
126
Population Rules for Mezzanine Cards
128
Installing Mezzanine Cards
134
Required Tools
134
Preliminary Steps
134
Installing a Mezzanine Card
135
Concluding Steps
139
Removing Mezzanine Cards
140
Required Tools
140
Preliminary Steps
140
Removing a Mezzanine Card
141
Concluding Steps
143
Replacing Mezzanine Cards
144
Required Tools
144
Preliminary Steps
144
Removing a Mezzanine Card
145
Installing a Mezzanine Card
145
Concluding Steps
145
8 Main Memory
147
Basic Information
148
Memory Sequence
148
Population Rules
148
Independent Channel Mode
150
Mirrored Channel and Performance Modes
152
Rank Sparing Mode
153
Installing Memory Modules
160
Required Tools
160
Preliminary Steps
160
Installing a Memory Module
161
Concluding Steps
162
Removing Memory Modules
164
Required Tools
164
Preliminary Steps
164
Removing a Memory Module
165
Concluding Steps
166
Replacing Memory Modules
167
Required Tools
167
Preliminary Steps
167
Removing a Memory Module
168
Installing a Memory Module
168
Concluding Steps
169
Handling of Memory Air Cowls
170
Installing the Air Cowls
170
Removing the Air Cowls
171
9 Processors
173
Basic Information
174
Installing Processors
174
Required Tools
174
Preliminary Steps
175
Installing a Processor
176
Concluding Steps
185
Removing Processors
186
Required Tools
186
Preliminary Steps
186
Removing a Processor
187
Concluding Steps
198
Upgrading or Replacing Processors
199
Required Tools
199
Preliminary Steps
199
Upgrading or Replacing a Processor
200
Removing the Processor
200
Installing the Processor
205
Concluding Steps
209
Handling Processor Heat Sinks
210
Required Tools
210
Preliminary Steps
210
Installing Processor Heat Sinks
211
Preparing the Heat Sink and Processor
213
Installing the Heat Sink for CPU 1
214
Installing the Heat Sink for CPU 2
217
Removing Processor Heat Sinks
219
Removing the "Dummy Heat Sink" of CPU 2
220
Replacing Processor Heat Sinks
221
Removing the Processor Heat Sink
221
Applying Thermal Paste
221
Installing the Processor Heat Sink
221
Concluding Steps
221
Applying Thermal Paste
222
10 System Board Components
225
Replacing the CMOS Battery
225
Required Tools
226
Preliminary Steps
226
Removing the Battery
227
Installing the CMOS Battery
229
Concluding Steps
230
USB Flash Module (UFM)
231
Installing the UFM
231
Required Tools
231
Preliminary Steps
231
Installing the UFM
232
Concluding Steps
234
Software Configuration
235
Removing the UFM
235
Required Tools
235
Preliminary Steps
236
Removing the UFM
237
Concluding Steps
237
Replacing the UFM
238
Required Tools
238
Preliminary Steps
238
Removing the UFM
239
Re-Installing the UFM
240
Concluding Steps
242
Software Configuration
242
Trusted Platform Module (TPM)
243
Installing the TPM
243
Required Tools
243
Preliminary Steps
243
Installing the TPM
244
Concluding Steps
247
Removing the TPM
249
Required Tools
249
Preliminary Steps
251
Removing the TPM
252
Concluding Steps
253
Replacing the TPM
254
Required Tools
254
Preliminary Steps
255
Removing the TPM
256
Re-Installing the TPM
256
Concluding Steps
256
Onboard SAS Enabling Key (SCU Key)
258
Required Tools
258
Preliminary Steps
258
Removing the Defective Onboard SAS Enabling Key
259
Installing the New Onboard SAS Enabling Key
260
Concluding Steps
262
Replacing the System Board
263
Required Tools
263
Preliminary Steps
265
Removing the System Board
266
Installing the System Board
268
Mounting the System Board
268
Concluding Steps
269
11 Server Blade
271
Replacing the Server Blade
271
Preliminary Steps
271
Replacing Steps
272
Concluding Steps
273
12 Appendix
275
Mechanical Overview
275
Server Blade Front
275
Server Blade Interior
276
Configuration Tables
277
Memory Configuration Table
277
Mezzanine Card Configuration Table
277
Connectors and Indicators
278
Connectors and Indicators on the System Board
278
Onboard Connectors
278
Onboard Settings
279
Onboard Indicators and Controls
280
Connectors and Indicators on the Front Panel
283
Front Panel Connectors
283
Front Panel Indicators
284
Minimum Startup Configuration
286
Advertisement
Share and save
Advertisement
Related Products
Fujitsu PRIMERGY BX924 S3
Fujitsu PRIMERGY BX922 S2
Fujitsu PRIMERGY BX924 S2
Fujitsu PRIMERGY BX920 S2
Fujitsu Primergy BX920 S3
Fujitsu Primergy BX920 S4
Fujitsu PRIMERGY BX920 S1
Fujitsu PRIMERGY BX900 S1
Fujitsu PRIMERGY BX960 S1
Fujitsu PRIMERGY BX900
Fujitsu Categories
Air Conditioner
Laptop
Server
Scanner
Storage
More Fujitsu Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL