1000Base-F And 100Base-F Fiber Installation - Alcatel-Lucent 1665 Installation Manual

Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Equipment and cable installation for 1665 Data Multiplexer
(1665 DMX)

1000Base-F and 100Base-F fiber installation

............................................................................................................................................................................................................................................................
Description
This section describes how to route the optical fiber cables from the interconnecting
equipment (for example, an LGX
LNW63, LNW64, LNW67, LNW68, LNW70, LNW74 and LNW78 Ethernet circuit
packs. Multi-mode optical fiber is required for LNW67 (1000 Base-F), LNW70 (100Base-
F ports) and LNW74 (100 Base-F ports). Single-mode fiber is required for LNW68 (1000
LX), LNW70 (1000Base-F ports) and LNW78(RPR) circuit packs.
The optical fiber cables will be connected to the optical ports after the circuit packs are
installed.
Important!
be placed in a protective tube or channel, such as PVC tubing, or PANDUIT cable
channel, when running the cable from the 1665 DMX High-Capacity shelf to the cable
rack. The fibers should be placed in the cable rack in a protective channel with nothing
on top of them. Cable ties should NOT be used with the optical fiber cables.
Unterminated optical connectors may emit laser radiation. Do not view an unterminated
optical connector with optical instruments.
Invisible laser radiation when unterminated. Avoid direct exposure of the eyes to the
beam.
Important!
examined to ensure that they are clean. See
recommended cleaning procedures.
Procedure
........................................................................................................................................................................................................................
Refer to the engineering job specification. Determine the function group (slot 1 only)
1
where the pack will be inserted. The LNW63, LNW64, LNW67, LNW68, LNW70,
LNW74 and LNW78 packs can be inserted into any of the function groups (slot 1)
including the growth slot (g1). In order to use the 10/100BaseT electrical ports on the
............................................................................................................................................................................................................................................................
1 - 9 2
®
optical fiber distributing frame) to the optical ports on
The optical fiber cable is fragile and must be protected. The fibers should
WARNING
Laser hazard
WARNING
Laser hazard
Prior to connecting the optical fiber cables, the fibers should be
1000Base-F and 100Base-F fiber installation
Appendix B, "Fiber cleaning"
for
365-372-304R7.1
Issue 1, November 2007

Advertisement

Table of Contents
loading