10.279 (ID 602) Field Weakening Point Frequency
Location in the menu:
•
P2.6.4 (Standard Application, Local/Remote Control Application, Multi-step Speed Control Application, PID Control Application,
Multi-purpose Control Application (VACON
•
P2.6.14.3 (Multi-purpose Control Application, VACON
Use this parameter to set the output frequency at which the output voltage reaches the field weakening point voltage.
10.280 (ID 603) Voltage at Field Weakening Point
Location in the menu:
•
P2.6.5 (Standard Application, Local/Remote Control Application, Multi-step Speed Control Application, PID Control Application,
Multi-purpose Control Application (VACON
•
P2.6.14.4 (Multi-purpose Control Application, VACON
Use this parameter to set the voltage at the field weakening point as a percentage of the motor nominal voltage.
Above the frequency at the field weakening point, the output voltage stays at the set maximum value. Below the frequency at the
field weakening point, the U/f curve parameters control the output voltage. See the parameters ID 109, ID 108, ID 604, andID 605.
When setting the parameters ID 110 and ID 111 (nominal voltage and nominal frequency of the motor), the parameters ID 602 and
ID 603 automatically receive related values. To have different values for the field weakening point and the maximum output volt-
age, change these parameters only after setting the parameters P3.1.1.1 and P3.1.1.2.
10.281 (ID 604) U/f Midpoint Frequency
Location in the menu:
•
P2.6.6 (Standard Application, Local/Remote Control Application, Multi-step Speed Control Application, PID Control Application,
Multi-purpose Control Application (VACON
•
P2.6.14.5 (Multi-purpose Control Application, VACON
Use this parameter to set the middle point frequency of the U/f curve.
If the value of ID 108 is programmable, this parameter gives the middle point frequency of the curve. See
ter ID 605.
10.282 (ID 605) U/f Midpoint Voltage
Location in the menu:
•
P2.6.7 (Standard Application, Local/Remote Control Application, Multi-step Speed Control Application, PID Control Application,
Multi-purpose Control Application (VACON
•
P2.6.14.6 (Multi-purpose Control Application, VACON
Use this parameter to set the middle point voltage of the U/f curve.
If the value of ID 108 is programmable, this parameter gives the middle point voltage of the curve. See
tion.
10.283 (ID 606) Output Voltage at Zero Frequency
Location in the menu:
•
P2.6.8 (Standard Application, Local/Remote Control Application, Multi-step Speed Control Application, PID Control Application,
Multi-purpose Control Application (VACON
•
P2.6.14.7 (Multi-purpose Control Application, VACON
Use this parameter to set the zero frequency voltage of the U/f curve.
The default value is different for different unit sizes.
If the value of parameter ID 108 is changed, this parameter is set to zero. See
10.284 (ID 607) Overvoltage Controller
Location in the menu:
Danfoss A/S © 2023.02
NXS), Pump and Fan Control Application)
®
NXP)
®
NXS), Pump and Fan Control Application)
®
NXP)
®
NXS), Pump and Fan Control Application)
®
NXP)
®
NXS), Pump and Fan Control Application)
®
NXP)
®
NXS), Pump and Fan Control Application)
®
NXP)
®
10.8 (ID 108) U/f Ratio Selec-
Illustration
25.
AB296635287482en-000301 / DPD00903 | 241
Parameter Descriptions
Illustration 25
and parame-
Need help?
Do you have a question about the VACON NX All-in-One and is the answer not in the manual?
Questions and answers