1Bb Configuration) - Fujitsu Oracle SPARC M12-2 Service Manual

Hide thumbs Also See for Oracle SPARC M12-2:
Table of Contents

Advertisement

Figure 3-12     System-Stopped/Cold Replacement in the SPARC M12-2S (1BB
(1) Removal of the
3.3.2
Types of Maintenance for FRU Addition (SPARC
M12-2S in the 1BB Configuration)
Table 3-9
and the applicable types of maintenance in the addition of each FRU.
Table 3-9     Applicable Types of Maintenance in FRU Addition to the SPARC M12-2S (1BB Configuration)
FRU
PCIe card
HDD/SSD
CMUU
Memory
PCI expansion unit
(chassis)
SPARC M12-2S (*1)
*1 The XSCF DUAL control cable, XSCF BB control cable, and crossbar cable need to be connected.
*2 When adding a SPARC M12-2S unit by using the PPAR DR function for the physical partition where Oracle Solaris is operating on the
existing SPARC M12-2S (1BB configuration)
*3 When adding a SPARC M12-2S unit into a physical partition different from the physical partition where Oracle Solaris is operating on
the existing SPARC M12-2S (1BB configuration)
*4 When adding a SPARC M12-2S unit when the existing physical partition is stopped
Active/Hot addition
Figure 3-13
M12-2S (1BB configuration).
50
Fujitsu SPARC M12-2/M12-2S Service Manual ・ January 2023
Configuration)
PPAR#00
SPARC M12-2S
Oracle Solaris
faulty FRU
lists the FRUs that can be added to the SPARC M12-2S (1BB configuration)
Active Addition
Hot
Cold
OK
-
OK
-
-
-
-
-
OK
-
-
OK (*2)
shows the state of the system during active/hot addition in the SPARC
(2) Installation of the
replacement FRU
FRU
FRU
Inactive Addition
Hot
Cold
-
-
-
-
-
-
-
-
-
-
-
OK (*3)
Hot
Cold
Running
Stopped
Normal
Faulty
-: Not applicable
System-Stopped Addition
Hot
Cold
OK
OK
OK
OK
-
OK
-
OK
OK
OK
-
OK (*4)