Active/Cold Replacement Workflow Of The Fanu - Fujitsu Oracle SPARC M12-2 Service Manual

Hide thumbs Also See for Oracle SPARC M12-2:
Table of Contents

Advertisement

4.2.4

Active/Cold Replacement Workflow of the FANU

You can perform active/cold replacement of the FANU in the following configuration:
Configuration connecting two or more SPARC M12-2S units to a physical partition
Before replacing the FANU, see
Precautions for FRU
Table 4-11
Table 4-11     Active/Cold Replacement Procedure of the FANU
Work
Order
1
2
3
4
5
6
7
8
9
10
11
12
Replacement."
shows the workflow for active/cold replacement of the FANU.
Task
Checking the operating condition of the
system and the I/O device usage status
Checking the logical domain assignment
status of CPU resources mounted in the
SPARC M12-2S requiring maintenance
Checking the logical domain assignment
status of memory resources mounted in
the SPARC M12-2S requiring maintenance
Releasing I/O resources of the SPARC
M12-2S requiring maintenance from a
logical domain
Releasing the SPARC M12-2S requiring
maintenance from the physical partition
Releasing the SPARC M12-2S requiring
maintenance from the building block
configuration
Placing the SPARC M12-2S requiring
maintenance into the cold state
Removing the FANU from the SPARC
M12-2S
Installing the FANU in the SPARC M12-2S
Placing the SPARC M12-2S that required
maintenance into the hot state
Incorporating the SPARC M12-2S that
required maintenance into the building
block configuration
Confirming that there is no problem with
the replacement FANU
"Precautions for FANU
Reference
"9.2 Checking the Operation Status and
Resource Usage Status of Oracle
"3.2.4 Checking the Assignment Status
of Resources" in the Fujitsu SPARC M12
and Fujitsu M10/SPARC M10 Domain
Configuration Guide
"3.2.4 Checking the Assignment Status
of Resources" in the Fujitsu SPARC M12
and Fujitsu M10/SPARC M10 Domain
Configuration Guide
"9.3 Releasing I/O Resources From a
Logical
Domain"
"9.4.3 Dynamically Releasing the
SPARC M12-2S From the Physical
Partition"
"9.6.1 Releasing the SPARC M12-2S
From the Building Block
"9.8.2 Removing the Power
"14.3.1 Removing a
"14.4.2 Installing a
"10.1.1 Installing a Power
"10.4.1 Incorporating the SPARC
M12-2S Into a Building Block
Configuration"
"10.5.3 Checking the FRU Status After
Maintenance"
Chapter 4 FRU Replacement Workflows
replacement" in
"7.1
Solaris"
Configuration"
Cords"
FANU"
FANU"
Cord"
81