When replacing a FANU, perform one of the maintenance procedures listed below.
[When replacing a FANU with the server in the hot state]
-
4.1.4 Active/Hot Replacement Workflow of the FANU
-
4.3.4 Inactive/Hot Replacement Workflow of the FANU
-
4.5.4 System-Stopped/Hot Replacement Workflow of the FANU
 
[When replacing a FANU with the server in the cold state]
-
4.2.4 Active/Cold Replacement Workflow of the FANU
-
4.4.4 Inactive/Cold Replacement Workflow of the FANU
-
4.5.4 System-Stopped/Hot Replacement Workflow of the FANU
14.3
Removing a FANU or the FANBPU
This section describes the procedure for removing a FANU or FANBPU.
Note - You can remove a FANU in the active state.
Note - You can remove the FANBPU only when the server is in the cold state.
14.3.1
Removing a FANU
This section describes the procedure for removing a FANU.
1.
Remove the front cover.
For the procedure for removing the front cover, see
Cover."
Note - The serial number of the server is printed on a label affixed on the front cover. Store
this cover such that it is not mixed up with the front covers of other SPARC M12 units.
2.
Pull up the latch of the FANU.
Pinch the latch of the FANU (A in
Figure
14-2) and pull it up.
Chapter 14 Maintaining the Fan Units and Fan Backplane Unit
"9.8.3 Removing the Front
405