To mount the SPARC M12-2S to be added in a rack, see "3.4.1 Mounting the SPARC
M12-2S in a Rack" in the Fujitsu SPARC M12-2S Installation Guide.
Table 5-9
shows the workflow for active/cold addition of the SPARC M12-2S.
Table 5-9     Active/Cold Addition Procedure of the SPARC M12-2S
Work
Task
Order
1
Checking the operating condition of the
system
2
Switching the mode switch on the OPNL
to Service
3
Incorporating the SPARC M12-2S into a
building block configuration (*1)
4
Diagnosing the added SPARC M12-2S (*2)
5
Diagnosing the XBU and crossbar cable
of the added SPARC M12-2S
6
Confirming that there is no problem with
the added SPARC M12-2S
7
Configuring memory mirroring if
duplicating memory
8
Adding the added SPARC M12-2S to the
PPAR configuration list for the physical
partition that is the incorporation
destination
9
Assigning the SPARC M12-2S (system
board) to the physical partition
10
Incorporating the SPARC M12-2S into the
physical partition
11
Switching the mode switch on the OPNL
to Locked
12
Assigning the resources of the added
SPARC M12-2S to logical domains
*1 Connect cables by following the workflow of the addfru command.
*2 If a SPARC M12-2S with no PCIe cards mounted was added, no diagnosis is necessary (because diagnosis was
performed in the previous step).
Reference
"9.2.1 Checking the Operation Status of
Physical Partitions and Logical
"2.3.2 OPNL Control
Function"
"10.3 Adding the SPARC M12-2S to a
Building Block
Configuration"
"10.5.1 Diagnosing the SPARC M12
Hardware"
"10.5.2 Diagnosing the XBU and
Crossbar
Cable"
"10.5.3 Checking the FRU Status After
Maintenance"
"7.6 Configuring Memory Mirroring" in
the Fujitsu SPARC M12-2S Installation
Guide
"7.7 Creating a PPAR Configuration
List" in the Fujitsu SPARC M12-2S
Installation Guide
"7.8.1 Assigning a Physical System
Board (PSB) to a Physical Partition
(PPAR)" in the Fujitsu SPARC M12-2S
Installation Guide
"10.6.1 Incorporating the SPARC
M12-2S Into the Physical Partition Using
PPAR
DR"
"2.3.2 OPNL Control
Function"
"3.2 Operations and Commands Related
to Logical Domain Configurations" in the
Fujitsu SPARC M12 and Fujitsu
M10/SPARC M10 Domain Configuration
Guide
Chapter 5 FRU Addition Workflows
Domains"
163