Table 4-29     Inactive/Cold Replacement Procedure of the XSCFU (continued)
Work
Task
Order
3
Confirming that the XSCFU to be
replaced is the standby or slave XSCF and
is currently replaceable (*1)
4
Powering off the physical partition
containing the SPARC M12-2S that
houses the XSCFU to be replaced
5
Switching the mode switch on the OPNL
to Service
6
Releasing the SPARC M12-2S requiring
maintenance from the building block
configuration
7
Placing the SPARC M12-2S requiring
maintenance into the cold state
8
Removing the XSCFU from the SPARC
M12-2S
9
Switching the SD card (*2)
10
Installing the XSCFU in the SPARC M12-2S
11
Placing the SPARC M12-2S that required
maintenance into the hot state
12
Incorporating the SPARC M12-2S that
required maintenance into the building
block configuration
13
Confirming that there is no problem with
the replacement XSCFU
14
Switching the mode switch on the OPNL
to Locked, and powering on the physical
partition containing the SPARC M12-2S
that has undergone maintenance
15
Checking the operating condition of the
system
*1 Before replacing the XSCFU, confirm that the READY LED of the XSCFU is lit in green or off. If the READY
LED of the XSCFU is blinking, wait until the LED stays lit or is turned off.
- If the XSCFU requiring replacement is not running when the physical partition containing the XSCFU is
powered on, perform active/hot replacement.
- If the physical partition containing the XSCFU requiring replacement is powered off, you can perform hot
replacement of the XSCFU even when it is not running. In that case, proceed to step 5.
*2 If the SD card installed in the maintenance part will be used, this work is not required.
Reference
"Table 2-16 XSCFU LEDs and Their
States"
"9.5.1 Stopping a Specific Physical
Partition"
"2.3.2 OPNL Control
Function"
"9.6.1 Releasing the SPARC M12-2S
From the Building Block
"9.8.2 Removing the Power
"11.4 Removing the
XSCFU"
"11.5 Switching an SD
"11.6 Installing the
XSCFU"
"10.1.1 Installing a Power
"10.4.1 Incorporating the SPARC
M12-2S Into a Building Block
Configuration"
"10.5.3 Checking the FRU Status After
Maintenance"
"10.8 Powering on a Physical
"9.2.1 Checking the Operation Status of
Physical Partitions and Logical
Chapter 4 FRU Replacement Workflows
Configuration"
Cords"
Card"
Cord"
Partition"
Domains"
105

Advertisement

Table of Contents
loading

This manual is also suitable for:

Oracle sparc m12-2s

Table of Contents