are incorporated in the logical domain guest.
primary # ldm list-bindings guest
NAME STATE FLAGS CONS VCPU MEMORY UTIL NORM UPTIME
guest inactive ------4 8G
UUID
d1055960-a4d0-4650-89ae-ae741b9fa2b8
-(Omitted)-
VARIABLES
auto-boot?=false
boot-device=vdisk0
NETWORK
NAME SERVICE ID DEVICE MAC MODE PVID VID MTU MAXBW LINKPROP
vnet0 primary-vsw0 0 00:14:4f:f8:48:67
DISK
NAME VOLUME TOUT ID DEVICE SERVER MPGROUP
vdisk0 vol0@primary-vds0 0
10.8
Powering on a Physical Partition
This section describes the procedure for powering on a physical partition.
Switch the mode switch on the OPNL to Locked mode.
1.
In a building block configuration connecting multiple SPARC M12-2S units,
switch the mode switch to Locked mode on the SPARC M12-2S units that house
the master XSCF and the standby XSCF, respectively.
Check the operation status of the physical partition.
2.
Log in to the XSCF shell, and check the operation status of the physical partition
by using the showpparstatus command.
This example checks that PPAR-ID#00 is powered off.
XSCF> showpparstatus -a
PPAR-ID PPAR Status
00
XSCF>
Power on the physical partition.
3.
From the XSCF shell, execute the poweron command to power on the physical
partition.
This example powers on PPAR-ID#0.
XSCF> poweron -p 0
Check the operation status of the physical partition.
4.
Check the operation status of the physical partition. This example checks that
368
Fujitsu SPARC M12-2/M12-2S Service Manual ・ January 2023
Powered Off
Need help?
Do you have a question about the Oracle SPARC M12-2 and is the answer not in the manual?