Table 6-17     Inactive/Cold Removal Procedure of a PCI Expansion Unit
Work
Task
Order
1
Checking the operating condition of the
system
2
Releasing the assignment of the I/O
resources of the PCIe cards mounted in
the PCI expansion unit to be removed
3
Confirming that you can remove the PCIe
cards mounted in the PCI expansion unit
to be removed (*1)
4
Saving logical domain configuration
information
5
Powering off the physical partition
containing the SPARC M12-2S that is
connected to the PCI expansion unit to be
removed
6
Switching the mode switch on the OPNL
to Service
7
Releasing the SPARC M12-2S connected
to the PCI expansion unit to be removed,
from the building block configuration
8
Releasing the PCI expansion unit to be
removed and the link card
9
Removing the PCICS in which the link
card is mounted from the SPARC M12-2S
10
Removing the link card from the PCICS
11
Installing a PCIe card filler in the PCICS,
and installing the PCICS in the SPARC
M12-2S
12
Incorporating the SPARC M12-2S from
which the PCI expansion unit was
removed into the building block
configuration
13
Powering on the physical partition
containing the SPARC M12-2S that
underwent maintenance
14
Confirming that there is no problem with
the system from which the PCI expansion
unit was removed
15
Switching the mode switch on the OPNL
to Locked
16
Checking the operating condition of the
physical partition and logical domains (*1)
Reference
"9.2.1 Checking the Operation Status of
Physical Partitions and Logical
"9.3 Releasing I/O Resources From a
Logical
Domain"
"9.2.1 Checking the Operation Status of
Physical Partitions and Logical
"9.1.1 Saving Logical Domain
Configuration
Information"
"9.5.1 Stopping a Specific Physical
Partition"
"2.3.2 OPNL Control
Function"
"9.6.1 Releasing the SPARC M12-2S
From the Building Block
Configuration"
"11.3 Removing a Link Cable" in the PCI
Expansion Unit for Fujitsu SPARC M12 and
Fujitsu M10/SPARC M10 Service Manual
"12.3.1 Enabling the Removal of a PCIe
Card"
"12.3.2 Removing a PCIe Card or PCIe
Card
Filler"
"12.4.1 Installing a PCIe Card or PCIe
Card
Filler"
"10.4.1 Incorporating the SPARC
M12-2S Into a Building Block
Configuration"
"10.9.1 Starting the System With an
XSCF
Command"
"10.5.3 Checking the FRU Status After
Maintenance"
"2.3.2 OPNL Control
Function"
"9.2.1 Checking the Operation Status of
Physical Partitions and Logical
Chapter 6 FRU Removal Workflows
Domains"
Domains"
Domains"
213

Advertisement

Table of Contents
loading

This manual is also suitable for:

Oracle sparc m12-2s

Table of Contents