Fujitsu Oracle SPARC M12-2 Service Manual page 237

Hide thumbs Also See for Oracle SPARC M12-2:
Table of Contents

Advertisement

Table 6-18     Inactive/Cold Removal Procedure of the SPARC M12-2S (continued)
Work
Order
10
*1 If the removal of the SPARC M12-2S does not affect logical domains, this work is not required.
*2 Reconfigure logical domains as required. For details, see "Chapter 3 Operations for Domain Configuration" in
the Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Domain Configuration Guide.
*3 Set the physical partition definitions again as required.
6.5
System-Stopped/Hot Removal
Workflows
This section describes the workflows for system-stopped/hot removal of the FRUs
mounted in the SPARC M12-2/M12-2S.
Before performing removal work, be sure to check the notes on maintenance work in
the Fujitsu SPARC M12 Product Notes of the XCP version used.
Each of the following sections puts together the order of work and the tasks for each
FRU into a table. For details on each task, see the reference shown in the table.
The following FRUs are subject to system-stopped/hot removal:
PCIe card
HDD/SSD
PCI expansion unit
6.5.1
System-Stopped/Hot Removal Workflow of a PCIe
Card
Before removing a PCIe card, see
Precautions for FRU
Table 6-19
Table 6-19     System-Stopped/Hot Removal Procedure of a PCIe Card
Work
Order
1
2
Task
Saving logical domain configuration
information
Reduction."
shows the workflow for system-stopped/hot removal of a PCIe card.
Task
Checking the operating condition of the
system
Checking the usage status of the PCIe
card to be removed
Reference
"9.1.1 Saving Logical Domain
Configuration
"Precautions for PCIe card
Reference
"9.2.1 Checking the Operation Status of
Physical Partitions and Logical
"9.2.2 Checking the Assignment Status
of I/O
Devices"
Chapter 6 FRU Removal Workflows
Information"
removal" in
"7.3
Domains"
215