Caution - When installing the PSUBP, make sure that it is kept horizontal and
perform the work carefully. Installing the PSUBP while it is tilted may damage the
PSUBP due to interference from the BPU components.
2.
Secure the PSUBP.
Tighten the three fixing screws to secure the PSUBP to the BPU.
Figure 18-18 Securing the PSUBP
3.
Connect the PSUBP to the BPU.
There are two connectors that connect the PSUBP and BPU. Install the connector
(black) shown in A of
B of
into the connector slot on the BPU side, with the latches closed, and then push it.
Once the connector is secured, the latches open.
476
Fujitsu SPARC M12-2/M12-2S Service Manual ・ January 2023
Figure 18-19
Figure
18-19. To install the connector shown in B of
first and then the connector (brown) shown in
Figure
18-19, insert it